A fix is available
APAR status
Closed as program error.
Error description
RECTRACE formats QPACSWITCH incorrectly and no indication of the QPACRUSM
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Batch Reporter users * **************************************************************** * PROBLEM DESCRIPTION: 1. Record trace displaying wrong values * * for fields QPACSWITCH, QJSTCIOF, * * QJSTBFFL, QJSTCIWR. * * 2. There are no indication when flag * * QPACRUSM is ON. * **************************************************************** * RECOMMENDATION: Apply the provided PTF. * **************************************************************** 1.Fields QPACSWITCH, QJSTCIOF, QJSTBFFL, QJSTCIWR are showing wrong values. 2.When flag QPACRUSM is ON field TYPE should show value ROLSUM.
Problem conclusion
1. Code amended to display correct values for QPACSWITCH, QJSTCIOF, QJSTBFFL, QJSTCIWR. 2. Logic is fixed to show ROLSUM when flag QPACRUSM is ON
Temporary fix
Comments
APAR Information
APAR number
PH47562
Reported component name
OM XE DB2PE/PM
Reported component ID
5655OPE00
Reported release
540
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2022-06-28
Closed date
2022-08-25
Last modified date
2022-09-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
BPOMAB01 BPOMADOB BPOMAXA0 DGONFISE DGONFPAC DGONFWAC DGONUPDB DGOVHMM1 DGOVMSTR KD5AGENT KD5ATC00 KDPBPRIX KDPH0006 KDPHBPD KDPINTVS KDPPLEX KDPPREG KDPTHD52 KDPTHDA2 KDPTHDBD KO2ABROW KO2ACONB KO2AFLTF KO2AFSAM KO2AGNTB KO2AHLR KO2AINIB KO2AOMBB KO2APC12 KO2APC1A KO2APC1K KO2APC1S KO2APC22 KO2APC2A KO2APC2K KO2APC2S KO2APC32 KO2APC3A KO2APC3K KO2APC3S KO2APC42 KO2APC4A KO2APC4K KO2APC4S KO2APC52 KO2APC5A KO2APC5K KO2APC5S KO2APC62 KO2APC6A KO2APC6K KO2APC6S KO2APC72 KO2APC7A KO2APC7K KO2APC7S KO2APC82 KO2APC8A KO2APC8K KO2APC8S KO2APC92 KO2APC9A KO2APC9K KO2APC9S KO2APCA2 KO2APCAA KO2APCAK KO2APCAS KO2APCB2 KO2APCBA KO2APCBK KO2APCBS KO2APCC2 KO2APCCA KO2APCCK KO2APCCS KO2APCE2 KO2APCEA KO2APCEK KO2APCES KO2APCF2 KO2APCFA KO2APCFK KO2APCFS KO2APCG2 KO2APCGA KO2APCGK KO2APCGS KO2APCH2 KO2APCHA KO2APCHK KO2APCHS KO2APCI2 KO2APCIA KO2APCIK KO2APCIS KO2APCJ2 KO2APCJA KO2APCJK KO2APCJS KO2APCK2 KO2APCKA KO2APCKK KO2APCKS KO2APCL2 KO2APCLA KO2APCLK KO2APCLS KO2APCM2 KO2APCMA KO2APCMK KO2APCMS KO2APCN2 KO2APCNA KO2APCNK KO2APCNS KO2APCO2 KO2APCOA KO2APCOK KO2APCOS KO2APCP2 KO2APCPA KO2APCPK KO2APCPS KO2APCQ2 KO2APCQA KO2APCQK KO2APCQS KO2APHLR KO2ARECB KO2ATABL KO2CCAPB KO2CIF32 KO2CIF3A KO2CIF3K KO2CIF3S KO2CIFI2 KO2CIFIA KO2CIFIK KO2CIFIS KO2CMRWB KO2CPC72 KO2CPC7A KO2CPC7K KO2CPC7S KO2CPCSB KO2NCSTB KO2ODINB KO2OINTB KO2ZOMI
Fix information
Fixed component name
OM XE DB2PE/PM
Fixed component ID
5655OPE00
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSZJXP","label":"DB2 Tools for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.4.0","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
01 September 2022