A fix is available
APAR status
Closed as program error.
Error description
ABEND0C4 in IPISPSCN with an invalid Start/Stop date range. When IMS Performance Analyzer encounters an invalid Start/Stop date range error message(s) IPI0424E are generated and normal control table creation is deferred until Prescan processing. When the Prescan routine (IPISPSCN) creates the control tables, a required base register for one of the tables is not loaded which causes the S0C4.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of IMS Performance Analyzer V4.5 * **************************************************************** * PROBLEM DESCRIPTION: Abend S0C4 IPISPSCN+94 * **************************************************************** Abend S0C4 in IPISPSCN with an invalid Start/Stop date range.
Problem conclusion
When IMS Performance Analyzer encounters an invalid Start/Stop date range error message(s) IPI0424E are generated and normal control table creation is deferred until Prescan processing. When the Prescan routine (IPISPSCN) creates the control tables a required base register for one of the tables is not loaded, leading to an abend S0C4 when subsequently referring to that table, the base register creation is corrected in this APAR.
Temporary fix
Comments
APAR Information
APAR number
PH47540
Reported component name
IMS PERF ANALYZ
Reported component ID
5655E1500
Reported release
450
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2022-06-27
Closed date
2022-07-06
Last modified date
2022-08-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI81327
Modules/Macros
IPISAPAR IPISPSCN
Fix information
Fixed component name
IMS PERF ANALYZ
Fixed component ID
5655E1500
Applicable component levels
R450 PSY UI81327
UP22/07/14 P F207
Fix is available