IBM Support

PH47368: IMAGE VPS CREATED ON THE SAME PAGE HAS THE SAME NAME WHICH MAKESDIFFICULT TO FIND ON PLAYBACK FAILURE

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 

APAR status

  • Closed as program error.

Error description

  • Image verification points created on the same page have the same
    display(control) name in a simplified script. After playback
    using Web UI engine, if any image VPs failed, it is difficult to
    find which VP is failed as all are having same display name.
    Earlier in XML reports, we provide additional information of VP
    Type and Property name to differentiate VPs.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * Rational Functional Tester users                             *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * See error description.                                       *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    

Problem conclusion

  • Previously, when you ran a functional test by using the
    simplified script, all the image verification points of a window
    were displayed with the same name in the unified report. As a
    result, it was difficult to identify the images of failed
    verification points. This problem is fixed.
    
    Now, Rational Functional Tester displays image verification
    point names in the following format:
    Verify Image <window_name> <verification_point_type>
    <property_name>
    
    The fix for this APAR is included in 10.5.0 release.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH47368

  • Reported component name

    RAT FUNC TESTER

  • Reported component ID

    5724G2503

  • Reported release

    A00

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2022-06-20

  • Closed date

    2022-09-26

  • Last modified date

    2022-09-26

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    RAT FUNC TESTER

  • Fixed component ID

    5724G2503

Applicable component levels