Error description

  • DRL0136W is issued when the collector is shutdown between SMF070
    records when they are split.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All IBM Z Performance and Capacity Analytics *
    *                 and IBM Z Decision Support users collecting  *
    *                 SMF_070 records.                             *
    ****************************************************************
    * PROBLEM DESCRIPTION: Receiving message DRL0136W when         *
    *                      starting or stopping the collector.     *
    ****************************************************************
    * RECOMMENDATION: Apply the provided PTF.                      *
    ****************************************************************
    If the collector is stopped between the first and last record
    when an SMF_070 is split, message DRL0136W is issued and the
    record is discarded.
    Additional diagnostic text in DRLDUMP:
    At shutdown: "Split SMF 70 orphaned at termination"
    At startup:  "Split SMF type 70: Initial record missing"
    

Problem conclusion

  • System table DRLCHECKPOINT has been added containing a Db2 BLOB
    for storing internal structures when a commit is performed. This
    will allow for information to be saved over a shutdown/startup
    and for better error recovery when restarting at the last commit
    point. Data in DRLCHECKPOINT is keyed by jobname. When a collect
    starts, it reads the data saved from the last time that jobname
    ran. For SMF_070 records, this will allow saving of incomplete
    split records.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH46966

  • Reported component name

    TDS FOR Z/OS

  • Reported component ID

    569510100

  • Reported release

    C01

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2022-06-03

  • Closed date

    2022-10-10

  • Last modified date

    2022-11-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI82764 UI82765

Modules/Macros

  • DRL1GDDM DRL1PGEN DRL1PRE  DRL1PSQL DRL1PTDS DRL1SQLX DRL2CICS
    DRL2CIST DRL2COMP DRL2CSQD DRL2CSQJ DRL2DCOL DRL2LOGJ DRL2MAJ2
    DRL2MAJ3 DRL2O400 DRL2OMEG DRL2S030 DRL2S042 DRL2S070 DRL2S078
    DRL2S104 DRL2S113 DRL2S30A DRL2S30O DRL2S42V DRL2S702 DRL2SA05
    DRL2SA07 DRL2SI06 DRL2SI08 DRL2TS77 DRL4CICS DRLEEXLC DRLEINI1
    DRLFPROF DRLPALLO DRLPALRE DRLPALRP DRLPALRX DRLPALUP DRLPCGAA
    DRLPCGB1 DRLPCGB2 DRLPCGCM DRLPCGCW DRLPCGGC DRLPCGGF DRLPCGGP
    DRLPCGGX DRLPCGJA DRLPCGJC DRLPCGJE DRLPCGLO DRLPCGLW DRLPCGNN
    DRLPCGO1 DRLPCGO2 DRLPCGO3 DRLPCGO4 DRLPCGP1 DRLPCGP2 DRLPCGPA
    DRLPCGPC DRLPCGPF DRLPCGPN DRLPCGPP DRLPCGRC DRLPCGSF DRLPCGSM
    DRLPCGSW DRLPCGWD DRLPCGXC DRLPCGXF DRLPCGXI DRLPCGXS DRLPCGXT
    DRLPCGXV DRLPCGZA DRLPCGZC DRLPCGZG DRLPCGZM DRLPCGZP DRLPCGZS
    DRLPCGZZ DRLPCIBM DRLPCKPT DRLPCMAA DRLPCMCM DRLPCMCR DRLPCMEV
    DRLPCMFP DRLPCMRN DRLPCMSC DRLPCMSP DRLPCMST DRLPCMSU DRLPCMSV
    DRLPCMZZ DRLPCOAI DRLPCOAS DRLPCOBI DRLPCOBU DRLPCOCF DRLPCOCR
    DRLPCOCS DRLPCODB DRLPCODI DRLPCOHA DRLPCOIT DRLPCOLL DRLPCOLO
    DRLPCOME DRLPCOMM DRLPCOMQ DRLPCOMR DRLPCOOT DRLPCOPC DRLPCOPR
    DRLPCORE DRLPCORX DRLPCOSF DRLPCOST DRLPCOUR DRLPCOUT DRLPCPRE
    DRLPCXAA DRLPCXCA DRLPCXCC DRLPCXCT DRLPCXFC DRLPCXFI DRLPCXIC
    DRLPCXID DRLPCXLD DRLPCXLO DRLPCXNN DRLPCXNU DRLPCXO1 DRLPCXO2
    DRLPCXO3 DRLPCXO4 DRLPCXPX DRLPCXSE DRLPCXUS DRLPCXVA DRLPCXVR
    DRLPDELO DRLPDEPU DRLPDERE DRLPDERP DRLPDEUP DRLPDICA DRLPDICC
    DRLPDICD DRLPDICI DRLPDICR DRLPDIRE DRLPDISP DRLPDISR DRLPDREC
    DRLPDROP DRLPDTAB DRLPFRFA DRLPFRFL DRLPFRFM DRLPFRFT DRLPFRLX
    DRLPFRSA DRLPFRSL DRLPFRSS DRLPIO   DRLPIO24 DRLPLC   DRLPLIIT
    DRLPLIIX DRLPLILI DRLPLIOB DRLPLIRE DRLPLIST DRLPLODT DRLPLOEX
    DRLPLOG  DRLPLOGC DRLPLOGM DRLPLOGS DRLPLOOU DRLPLOPC DRLPLOPE
    DRLPLOPF DRLPLOPR DRLPLOST DRLPNCCI DRLPNCCR DRLPNCCS DRLPNCDF
    DRLPPAER DRLPPAEX DRLPPAFI DRLPPARS DRLPPGEN DRLPPSQL DRLPPURG
    DRLPRECA DRLPRECB DRLPRECO DRLPRECS DRLPRECX DRLPREEX DRLPREIX
    DRLPRENX DRLPRPRO DRLPRPRS DRLPSCAN DRLPSCMA DRLPSCRT DRLPSECF
    DRLPSECN DRLPSECT DRLPSET  DRLPSQL  DRLPSQLA DRLPSQLD DRLPSQLE
    DRLPSQLI DRLPSQLM DRLPSQLO DRLPSQLS DRLPSQLT DRLPSQLX DRLPSQLZ
    DRLPSTEX DRLPSVIP DRLPTABL DRLPTANR DRLPTANV DRLPTDCD DRLPTDCS
    DRLPTDCT DRLPTDID DRLPTDIS DRLPTDIT DRLPTDRD DRLPTDRS DRLPTDRT
    

Fix information

  • Fixed component name

    TDS FOR Z/OS

  • Fixed component ID

    569510100

Applicable component levels

  • R901 PSY UI82765

       UP22/10/12 P F210

  • RC01 PSY UI82764

       UP22/10/12 P F210

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS2DUM","label":"IBM Z Decision Support"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"C01","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date:
01 November 2022