Error description

  • S702 abend posting heartbeat after "quick" ending
    
    
    The capture service abended S702-08 trying to post an ECB.  The
    ECB pointer had once pointed at the heartbeat timer ECB
    for a subscription, but that storage has been reused to have
    a string in the storage.  The linkage stack for the PC into
    POST registers provide the traceback and show the abend is from
    the timer manager and the abend is because the storage was
    reused and the subscription's pointer wasn't reset.
    
    The subscription was in an internal ending state of "quick" end
    following an error.  The error was from the IMS log
    reader.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Classic CDC for IMS, Version 11.3            *
    *                 Classic CDC for VSAM, Version 11.3           *
    *                 VSAM Remote Source, Version 11.4             *
    ****************************************************************
    * PROBLEM DESCRIPTION: S702 abend posting heartbeat after      *
    *                      "quick" ending                          *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    The capture service abended S702-08 trying to post an ECB. The
    ECB pointer had once pointed at the heartbeat timer ECB for a
    subscription, but that storage has been reused to have a string
    of character data in the same storage.
    The linkage stack for the PC into POST registers provide the
    traceback and show the abend is from the timer manager and the
    abend is because the storage was reused and the subscription's
    pointer wasn't reset.
    

Problem conclusion

  • The pointer address is cleared on a quick ending.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH45968

  • Reported component name

    CLASSIC FED & E

  • Reported component ID

    5697I8200

  • Reported release

    B30

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2022-04-28

  • Closed date

    2022-05-03

  • Last modified date

    2022-06-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI80391

Modules/Macros

  •    CECREPL2
    

Fix information

  • Fixed component name

    CLASSIC FED & E

  • Fixed component ID

    5697I8200

Applicable component levels

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"InfoSphere Classic Federation Server for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"B30"}]

Document Information

Modified date:
06 July 2022