A fix is available
APAR status
Closed as program error.
Error description
After applying recent maintenance, the latency may be observed to increase by one or two seconds during high workload replication, this is not acceptable to highly latency sensitive customers.
Local fix
No.
Problem summary
**************************************************************** * USERS AFFECTED: All users of InfoSphere CDC for z/OS. * **************************************************************** * PROBLEM DESCRIPTION: When Db2 indicates to CDC that there is * * no more data, an internal initial log * * poll interval of half a second is set * * by the CDC log reader task before the * * configured LOGPOLLINTERVAL is used. * * This is done to achieve low latency * * when there are short intervals of no * * log data, however for customers who are * * highly sensitive to latency issues the * * half second initial interval is too * * large. It may cause overall latency to * * be increased for one or two seconds in * * some situations. * **************************************************************** Slight latency increase may be observed for IIDR CDC for DB2 z/OS after applying recent PTFs.
Problem conclusion
The internal initial log poll interval was reduced to a lower value with limited effect on CPU use.
Temporary fix
Comments
APAR Information
APAR number
PH45587
Reported component name
INFO SRVR CDC Z
Reported component ID
5655U7600
Reported release
A21
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2022-04-11
Closed date
2022-04-12
Last modified date
2022-05-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI80101
Modules/Macros
CHCDLRGP CHCDSLGP
Fix information
Fixed component name
INFO SRVR CDC Z
Fixed component ID
5655U7600
Applicable component levels
RA21 PSY UI80101
UP22/04/16 P F204
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":"LOB10","label":"Data and AI"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSTVMA","label":"InfoSphere Data Replication for DB2 for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"10.2.1"}]
Document Information
Modified date: