IBM Support

PH45278: DATA LOSS RUNNING THE CONTINUOUS COLLECTOR

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Data appears to be lost running the Continuous Collector.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of IBM Z Decision Support and      *
    *                 IBM Z Performance and Capacity Analytics     *
    *                 running the Continuous Collector.            *
    ****************************************************************
    * PROBLEM DESCRIPTION: After message DRL0382I Logstream        *
    *                      closed and reopened a data loss         *
    *                      may occur.                              *
    ****************************************************************
    * RECOMMENDATION: Apply the PTF provided.                      *
    ****************************************************************
    The code to close and reopen the logstream logic incorrectly
    positioned at the start of the read loop.
    

Problem conclusion

  • The logstream close and reopen logic is moved to the end of the
    read loop.
    The MODIFY LOGSTREAM FREE commands have been back fitted to
    IBM Z Decision Support.
    A new option of the MODIFY command enables the frequency of the
    logstream close and reopen to be changed.
    
    Due to the overhead in closing and re-opening a logstream
    this function is no longer started automatically when the
    Continuous Collector is started. If required this function may
    be started manually with the MODIFY command at an interval
    of the customers choice. If the function is not required to
    run continually it may be issued ad-hoc with the NOW option
    of the MODIFY command.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH45278

  • Reported component name

    TDS FOR Z/OS

  • Reported component ID

    569510100

  • Reported release

    901

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2022-03-29

  • Closed date

    2022-06-29

  • Last modified date

    2022-08-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI81207 UI81208

Modules/Macros

  • DRL2CICS DRL2CIST DRL2COMP DRL2CSQD DRL2OMEG DRLPCOB2 DRLPCOBI
    DRLPCOBU DRLPCOCF DRLPCODB DRLPCOHA DRLPCOIT DRLPCOLL DRLPCOLO
    DRLPCOME DRLPCOMQ DRLPCOPC DRLPCOPR DRLPCORE DRLPCORX DRLPCOSF
    DRLPCOST DRLPCOUR DRLPCOUT DRLPDISP DRLPLIIT DRLPLIST DRLPLOGC
    DRLPLOGS DRLPLOPC DRLPLOPR DRLPMG00 DRLPRECA DRLPUPDS DRLPXDBG
    DRLSD100 DRLSD101 DRLSD102 DRLSD64D DRLSIB1F DRLSIB1I DRLSIB1L
    DRLSIB1V DRLSIB1Z DRLSIC1F DRLSIC1I DRLSIC1L DRLSIC1V DRLSIC1Z
    DRLSID1F DRLSID1I DRLSID1L DRLSID1V DRLSID1Z DRLSIE1F DRLSIE1I
    DRLSIE1L DRLSIE1V DRLSIE1Z DRLSIF1F DRLSIF1I DRLSIF1L DRLSIF1V
    DRLSIF1Z DRLSLOPR
    

Fix information

  • Fixed component name

    TDS FOR Z/OS

  • Fixed component ID

    569510100

Applicable component levels

  • R901 PSY UI81208

       UP22/07/09 P F207

  • RC01 PSY UI81207

       UP22/07/09 P F207

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS2DUM","label":"IBM Z Decision Support"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"901","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date:
02 August 2022