Error description
HP Load issues HPSR0010W when HALDB has only one segment occurrence. HPSR0010W NO SEGMENT WAS READ FROM INPUT
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of IBM IMS High Performance Load * * for z/OS Version 2 Release 1 (FMID=H1IM210). * **************************************************************** * PROBLEM DESCRIPTION: HP Load issues HPSR0010W when HALDB has * * only one segment occurrence. * * HPSR0010W NO SEGMENT WAS READ FROM * * INPUT * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** HP Load issues HPSR0010W and ends with RC=04 when HALDB has only one segment occurrence. HPSR0010W NO SEGMENT WAS READ FROM INPUT HP Load will also not issue HPSR0010W and ends with RC=00 if there is no segment occurrence in HALDB and PARTINIT=YES is specified and DBDS is initialized. This is due to a problem in determining whether the number of segment occurrences is zero.
Problem conclusion
HP Load has been changed to correctly determine the number of segment occurrence.
Temporary fix
Comments
APAR Information
APAR number
PH44979
Reported component name
IMS HP LOAD
Reported component ID
5655E0700
Reported release
210
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2022-03-17
Closed date
2022-03-27
Last modified date
2022-04-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI79897
Modules/Macros
HPSRHRP2 HPSRHRP3 HPSRHRP4 HPSRHRP5 HPSRHRP7 HPSRHRP8 HPSRHRP9 HPSRHRPA HPSRHRPB
Fix information
Fixed component name
IMS HP LOAD
Fixed component ID
5655E0700
Applicable component levels
R210 PSY UI79897
UP22/03/29 P F203
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":"LOB10","label":"Data and AI"},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX89F","label":"IMS Tools"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.1.0"}]
Document Information
Modified date: