A fix is available
APAR status
Closed as program error.
Error description
1. ABEND80A in IPISIRUR obtaining 24-bit working storage areas for report processing. S80A 2. Internal Resource Usage Report (IRUR) IRLM System extract headings truncated.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of IMS Performance Analyzer V4.5 * **************************************************************** * PROBLEM DESCRIPTION: Abend S80A/S878 IPISIRUR+8A38 * **************************************************************** Abend S80A in IPISIRUR obtaining 24-bit working storage area for report processing.
Problem conclusion
1. The IMS PA IRUR report obtains working storage for each IMS system it reports on, this storage is currently in 24-bit storage below the line, this is changed to now be 31-bit storage above the line. In addition, buffer pool control blocks for input files currently in 24-bit storage are changed to use 31-bit storage and IMS PA Transit Engine queue manager control blocks residing in 24-bit storage are now moved to 31-bit storage. 2. The IRLM System CSV extract headers may be truncated if the IRLM User extract is processed beforehand as they share a common set of headers and the default length was not reset before each report was processed.
Temporary fix
Comments
×**** PE22/07/20 FIX IN ERROR. SEE APAR PH48137 FOR DESCRIPTION
APAR Information
APAR number
PH44912
Reported component name
IMS PERF ANALYZ
Reported component ID
5655E1500
Reported release
450
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2022-03-15
Closed date
2022-04-06
Last modified date
2022-08-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI80032
Modules/Macros
IPI4QMGR IPISAPAR IPISIRUR IPISIRUX IPISMCOP IPISMERG
Fix information
Fixed component name
IMS PERF ANALYZ
Fixed component ID
5655E1500
Applicable component levels
R450 PSY UI80032
UP22/04/09 P F204
Fix is available