A fix is available
APAR status
Closed as program error.
Error description
In some cases when the reference-modified length is greater than one, the TALLYING result in identifier-2 is computed incorrectly. USERS AFFECTED: Users of Enterprise COBOL 6.2 compiling and running programs containing format 1 of the INSPECT statement (INSPECT TALLYING without the REPLACING phrase) where identifier-1 is a reference-modified LINKAGE SECTION item whose PICTURE clause is PICTURE X(1), and compiling with the OPT(1) or OPT(2) compiler option.
Local fix
BYPASS/CIRCUMVENTION A possible workaround is to change the PICTURE X(1) item to PICTURE X(n) where n is the largest reference-modified length used at runtime.
Problem summary
**************************************************************** * USERS AFFECTED: Users of Enterprise COBOL 6.3 compiling and * * running programs containing format 1 of the * * INSPECT statement (INSPECT TALLYING without * * the REPLACING phrase) where identifier-1 is * * a reference-modified LINKAGE SECTION item * * whose PICTURE clause is PICTURE X(1), and * * compiling with the OPT(1) or OPT(2) compiler * * option. * **************************************************************** * PROBLEM DESCRIPTION: In some cases when the * * reference-modified length is greater * * than one, the TALLYING result in * * identifier-2 is computed incorrectly. * **************************************************************** * RECOMMENDATION: Apply the provided PTF. * **************************************************************** In the case identified above the compiler was generating incorrect code that resulted in identifier-2 of the TALLYING phrase being computed incorrectly.
Problem conclusion
The compiler was changed to generate the correct code.
Temporary fix
Comments
APAR Information
APAR number
PH44900
Reported component name
ENT COBOL FOR Z
Reported component ID
5655EC600
Reported release
630
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2022-03-15
Closed date
2022-03-15
Last modified date
2022-04-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
IGY8RWTU IGYCASMB IGYCCBE IGYCCCRT IGYCCICS IGYCCSRV IGYCDGEN IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4 IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8 IGYCJA$D IGYCJA$R IGYCLIBR IGYCLSTR IGYCLVL0 IGYCLVL1 IGYCLVL2 IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOSCN IGYCPGEN IGYCRCTL IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT IGYCSCAN IGYCSIMD IGYCUE$0 IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8 IGYCUE$D IGYCUE$R IGYCXREF IGYDRV IGYEQCWI IGYMSGE IGYMSGK IGYMSGT IGYQCB IGYQCBE IGYQCBG IGYQSPLT IGYTCARA IGYTSALE IGYZQEN6 IGYZQENU IGYZQJP6 IGYZQJPN
Fix information
Fixed component name
ENT COBOL FOR Z
Fixed component ID
5655EC600
Applicable component levels
R630 PSY UI79731
UP22/03/26 P F203
R631 PSY UI79732
UP22/03/26 P F203
R632 PSY UI79733
UP22/03/26 P F203
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"630","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date: