A fix is available
APAR status
Closed as program error.
Error description
Run IZDS 190 Continuous Collector with zIIP enabled. Issue modify command to pause collector and it abends.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All IZDS users of the Continuous Collector. * **************************************************************** * PROBLEM DESCRIPTION: The Continuous Collector abends when * * issuing the pause command if zIIP is * * enabled. * **************************************************************** * RECOMMENDATION: Apply the provided PTF(s). * **************************************************************** The function to issue WTOs did not switch to TCB mode before issuing the SVC.
Problem conclusion
The function to issue WTOs now switches to TCB mode before issuing the SVC.
Temporary fix
Comments
APAR Information
APAR number
PH44747
Reported component name
TDS FOR Z/OS
Reported component ID
569510100
Reported release
901
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2022-03-08
Closed date
2022-03-15
Last modified date
2022-04-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI79730
Modules/Macros
DRLPLOPC
Fix information
Fixed component name
TDS FOR Z/OS
Fixed component ID
569510100
Applicable component levels
R901 PSY UI79730
UP22/03/17 P F203
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":"LOB35","label":"Mainframe SW"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS2DUM","label":"IBM Z Decision Support"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"901"}]
Document Information
Modified date:
02 April 2022