Error description
Prevent raising PG0400 / APGC abend when an invalid pta_container_storage_size is encountered
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: All CICS users. * **************************************************************** * PROBLEM DESCRIPTION: Prevent a false PG0400 / APGC abend * * being issued when an invalid value * * is in pta_container_storage_size. * **************************************************************** CICS keeps count of container storage size in use by a task in PTA control block field pta_container_storage_size. DFHPGCR checks if a new container request will result in this field exceeding 5% of the job's MEMLIMIT. If it does, the task abends with DFHPG0400 and a APGC abend. If decrementing pta_container_storage_size produces a value below 0, the PGCR check sees this as a large number and abends the task with PG0400 / APGC.
Problem conclusion
DFHPGCH and DFHPGCR have been changed to make field pta_container_storage_size 0 if a decrement takes the value below 0.
Temporary fix
Comments
APAR Information
APAR number
PH44664
Reported component name
CICS TS Z/OS V5
Reported component ID
5655Y0400
Reported release
100
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2022-03-04
Closed date
2022-06-07
Last modified date
2022-09-08
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI80907 UI80908 UI80909
Modules/Macros
DFHPGCH DFHPGCR DFHXCCH DFHXCCR
Fix information
Fixed component name
CICS TS Z/OS V5
Fixed component ID
5655Y0400
Applicable component levels
R100 PSY UI80909
UP22/06/08 P F206
R200 PSY UI80908
UP22/06/08 P F206
R300 PSY UI80907
UP22/06/15 P F206