A fix is available
APAR status
Closed as program error.
Error description
Receiving ASOD abends in DFHXMAB at system startup. Trace: 000003 00040 SO 0E1C SOUS *EXC* - GETSOCKNAME_FAILURE RETURN_VALUE(-1) RETURN_CODE(1124) REASON_CODE(749B0000) KE_NUM-006D The dump shows that the connection was already gone before CSOL had managed to attach CIEP. We have fixed a similar issue in the past for IPIC connections (PI24245). This new APAR will allow us to extend this part of the PI24245 fix to cover ECI connections in addition to IPIC ones. Additional Symptom(s) Search Keyword(s): KIXREVDAM ABENDASOD
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All CICS users. * **************************************************************** * PROBLEM DESCRIPTION: An ASOD abend and TCPIPSERVICE * * closed after an initial attempt to * * acquire an ECI connection and then the * * socket is closed before being * * processed by CSOL. * **************************************************************** An attempt is made to acquire an ECI connection. Before the socket is processed by CSOL, it is closed by another process, maybe not even by CICS. This results in a GETSOCKNAME call from DFHSOLS failing. DFHSOLS does not handle the failure properly and continues as though the call was successful so task CIEP is attached and then fails with an ASOD abend from program DFHXMAB. The TCPIPSERVICE is then closed.
Problem conclusion
DFHSOLS has been changed so that if a GETSOCKNAME call fails for the ECI protocol, no CIEP task is attached and the TCPIPSERVICE is not closed.
Temporary fix
Comments
APAR Information
APAR number
PH44299
Reported component name
CICS TS Z/OS V5
Reported component ID
5655Y0400
Reported release
200
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2022-02-18
Closed date
2022-04-28
Last modified date
2022-05-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI80333 UI80334 UI80335 UI80336
Modules/Macros
DFHSOLS DFHWS002 DFHWS003 DFHWS004 DFHWS005 DFHWS006 DFHWS007 DFHWS008 DFHWS009 DFHWS010 DFHWS011 DFHWS012 DFHWS013 DFHWS014 DFHWS015 DFHWS016 DFHWS017 DFHWS018 DFHWS019 DFHWS020 DFHWS021 DFHWS022 DFHWS023 DFHWS024 DFHWS025 DFHWS026 DFHWS027 DFHWS028 DFHWS029 DFHWS030 DFHWS031 DFHWS032 DFHWS033 DFHWS034 DFHWS035 DFHWS036 DFHWS037 DFHWS038 DFHWS039 DFHWS040 DFHWS041 DFHWS042 DFHWS043 DFHWS044 DFHWS045 DFHWS046 DFHWS047 DFHWS048 DFHWS049 DFHWS050 DFHWS051 DFHWS052 DFHWS053 DFHWS054 DFHWS055 DFHWS056 DFHWS057 DFHWS058 DFHWS059 DFHWS060 DFHWS061 DFHWS062 DFHWS064 DFHWS065 DFHWS066 DFHWS068 DFHWS069 DFHWS070 DFHWS071 DFHWS072 DFHWS073 DFHWS074 DFHWS075 DFHWS076 DFHWS077 DFHWS078 DFHWS079 DFHWS081 DFHWS082 DFHWS083 DFHWS084 DFHWS085 DFHWS086 DFHWS087 DFHWS088 DFHWS089 DFHWS090 DFHWS091 DFHWS092 DFHWS122 DFHWS123
Fix information
Fixed component name
CICS TS Z/OS V5
Fixed component ID
5655Y0400
Applicable component levels
R200 PSY UI80335
UP22/04/29 P F204
R20W PSY UI80336
UP22/04/29 P F204
R300 PSY UI80333
UP22/05/02 P F204
R30W PSY UI80334
UP22/05/02 P F204
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":"LOB35","label":"Mainframe SW"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.5"}]
Document Information
Modified date:
04 May 2022