PH43532: GIM23901E ** LINK-EDIT PROCESSING FOR SYSMOD UI70006 FAILED FOR MODULE CPAOLSAM IN LMOD CPAOLSAM IN THE ACPAMOD LIBRARY. RC12

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When installing CICS PA the after the Accept Check had a RC of 0
    this message is produced - IEW2736S DA10 THERE IS NO SPACE LEFT
    IN THE DIRECTORY FOR DDNAME ACPAMOD. STOW OF THE DIRECTORY ENTRY
    MEMBER NAME CPARSPUT FAILED.
    
    The PDS directory entry for the specified primary member name
    could not be stored because the directory ran out of space. The
    sample JCL should be coded to have the amount of directory space
    needed for this new install.
    
    The following message was also produced:
    GIM23901E ** LINK-EDIT PROCESSING FOR SYSMOD UI70006 FAILED FOR
    MODULE CPAOLSAM IN LMOD CPAOLSAM IN THE ACPAMOD LIBRARY.   THE
    RETURN CODE (12) EXCEEDED THE ALLOWABLE VALUE.
    
    Additional Symptom(s) Search Keyword(s): KIXREVSVR
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of CICS PA V5.4                    *
    ****************************************************************
    * PROBLEM DESCRIPTION: During the installation of CICS PA,     *
    *                      when the PTFs are being ACCEPTed,       *
    *                      message GIM23901E is produced.          *
    ****************************************************************
    In the lifetime of CICS PA 5.4 there has been a number of PTFs
    that have made changes to the product, resulting in the number
    of tracks specified for ACPAMOD and SCPALINK in the sample
    installation job CPALLOC being too small. Customers using the
    job without modification would see message GIM23901E when the
    PTFs are ACCEPTed.
    

Problem conclusion

  • CPALLOC has been changed to increase the track sizes for ACPAMOD
    and SCPALINK.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH43532

  • Reported component name

    CICS PERF ANALY

  • Reported component ID

    5655Y2300

  • Reported release

    540

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2022-01-21

  • Closed date

    2022-02-08

  • Last modified date

    2022-03-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI79212

Modules/Macros

  • CPAALLOC
    

Fix information

  • Fixed component name

    CICS PERF ANALY

  • Fixed component ID

    5655Y2300

Applicable component levels

  • R540 PSY UI79212

       UP22/02/09 P F202

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.