IBM Support

PH43491: CICS TRANS CWBA ABEND ASP9 IN PRG CCVWSPMI WHEN CCVBMAIN UTILITYDEPLOY REPORT SPECIFIES &(AMPERSAND) IN PARM VAL FOR CONNECTION

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • A CCVBMAIN batch utility DEPLOY COLDSTARTCOMPARE report is
    submitted. The CONNECTION parameter incorrectly specifies an
    & (ampersand) in its parameter value.
    
    The CCVBMAIN DEPLOY job step fails RC=08 with information
    message
    "CCV9147I ... CCVBMAIN ended unsuccessfully with Return code 8";
    and no other error message appears.
    
    The CICS region MSGUSR output shows that CICS transaction CWBA
    failed with ABEND ASP9 in program CCVWSPMI.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of CICS Configuration Manager.     *
    ****************************************************************
    * PROBLEM DESCRIPTION: CICS transaction CWBA ABEND ASP9 in     *
    *                      program CCVWSPMI when a CCVBMAIN        *
    *                      utility DEPLOY report specifies &       *
    *                      (ampersand) in the parameter value for  *
    *                      CONNECTION.                             *
    ****************************************************************
    A CCVBMAIN batch utility DEPLOY COLDSTARTCOMPARE report is
    submitted.  The CONNECTION parameter incorrectly specifies an
    & (ampersand) in its parameter value.
    
    The CCVBMAIN DEPLOY job step fails RC=08 with information
    message
    "CCV9147I ... CCVBMAIN ended unsuccessfully with Return code 8";
    and no other error message appears.
    
    The CICS region MSGUSR output shows that CICS transaction CWBA
    failed with ABEND ASP9 in program CCVWSPMI.
    

Problem conclusion

  • CICS Configuration Manager is corrected.  The validation checks
    for the DEPLOY statement parameters CONNECTION and others is
    improved. A CONNECTION value including & (ampersand) is rejected
    with errors.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH43491

  • Reported component name

    CICS CONFIG MGR

  • Reported component ID

    5697CIC00

  • Reported release

    540

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2022-01-19

  • Closed date

    2022-03-18

  • Last modified date

    2022-04-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI79801 UI79802 UI79803

Modules/Macros

  • CCVBMAIN CCVSMSGE CCVSMSGK
    

Fix information

  • Fixed component name

    CICS CONFIG MGR

  • Fixed component ID

    5697CIC00

Applicable component levels

  • R540 PSY UI79801

       UP22/03/22 P F203

  • R54E PSY UI79802

       UP22/03/22 P F203

  • R54K PSY UI79803

       UP22/03/22 P F203

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":"LOB35","label":"Mainframe SW"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS2L7A","label":"CICS Configuration Manager for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.4"}]

Document Information

Modified date:
02 April 2022