IBM Support

PH43476: HLO3857E MESSAGE ON A CONSISTENT LOAD OR IMAGE COPY LOAD JOB EVEN WHEN THE LOADLIB IS APF AUTHORIZED

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Consistent Load or Image Copy load job may fail with the
    following message even when the loadlib data set is APF
    authorized.
    
    HLO3857E The following dataset in the Db2 loadlibs concatenation
    is not APF authorized: <data set>
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users                                    *
    ****************************************************************
    * PROBLEM DESCRIPTION: Potential S378 ABEND when module        *
    *                      HLO$SV26 is invoked                     *
    ****************************************************************
    Potential S378 ABEND when module HLO$SV26 is invoked
    

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    PH43476

  • Reported component name

    IDAA LOADER ZOS

  • Reported component ID

    5639OLA00

  • Reported release

    210

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2022-01-20

  • Closed date

    2022-02-26

  • Last modified date

    2022-04-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • HLO#A001 HLO#ACIR HLO#ACIW HLO#ACON HLO#ACRD HLO#ACUP HLO#ADIS
    HLO#ADSC HLO#AEXT HLO#AFMT HLO#AFRR HLO#ALLO HLO#AMIN HLO#AOBP
    HLO#ASYS HLO#AUMX HLO#AUTO HLO#BCLR HLO#BCTC HLO#BIND HLO#BPRI
    HLO#BRS  HLO#BSQL HLO#BTMP HLO#BULD HLO#CARD HLO#CHKR HLO#CL
    HLO#CL64 HLO#CL7  HLO#CL8  HLO#CLLS HLO#CMTS HLO#CNTL HLO#CPM
    HLO#CPNT HLO#CPOL HLO#DB2V HLO#DCMD HLO#DISP HLO#DSAF HLO#DSPL
    HLO#DYNL HLO#ECIC HLO#EMCS HLO#EMIC HLO#EMID HLO#ENCR HLO#ENQS
    HLO#ENVF HLO#EPRI HLO#FCPY HLO#ICAI HLO#ICAL HLO#ICCC HLO#ICCI
    HLO#ICP7 HLO#ICP8 HLO#ICPO HLO#IDCF HLO#IDSA HLO#IERR HLO#IHSA
    HLO#IKPL HLO#IKPN HLO#ILGP HLO#ILRA HLO#ILRS HLO#ILSA HLO#INIT
    HLO#IOPF HLO#IPIE HLO#IPPB HLO#IPPC HLO#IPPD HLO#IPPH HLO#IPPL
    HLO#IPPN HLO#IPPS HLO#IRPL HLO#ISNA HLO#IX   HLO#IX10 HLO#IX7
    HLO#IX8  HLO#IX9  HLO#IXN8 HLO#IXP7 HLO#IXP8 HLO#IXP9 HLO#IXPT
    HLO#JPRI HLO#LGAA HLO#LGAC HLO#LGAF HLO#LGAI HLO#LGAP HLO#LOGR
    HLO#LPIO HLO#LRD6 HLO#LRPT HLO#MAIN HLO#MDRV HLO#MLOG HLO#MMGR
    HLO#MPRI HLO#MREP HLO#MTIO HLO#NREC HLO#OBEX HLO#OPCL HLO#OPRI
    HLO#OPVD HLO#OS   HLO#OUT2 HLO#PDEP HLO#PITS HLO#PLOG HLO#PRNG
    HLO#PRSE HLO#QSAM HLO#RANG HLO#RCFS HLO#RESM HLO#RH   HLO#RH10
    HLO#RM24 HLO#RPRP HLO#RUNT HLO#SCHD HLO#SCPY HLO#SETP HLO#SETR
    HLO#SQLE HLO#STAT HLO#SUBD HLO#SUBX HLO#SYSC HLO#TABL HLO#TB
    HLO#TB7  HLO#TB8  HLO#TBPT HLO#TP   HLO#TP10 HLO#TS   HLO#TS10
    HLO#TS7  HLO#TS8  HLO#TS9  HLO#TSS  HLO#TSSA HLO#TUTL HLO#UPRI
    HLO#UTED HLO#UTLL HLO#UTLS HLO#UTOB HLO#UTOP HLO#VERS HLO#VERT
    HLO#VSAM HLO#VSM  HLO#WRIT HLO#XMLC HLO#XMLI HLO#XMLJ HLO#XMLS
    HLO$ACCS HLO$ACES HLO$ADM2 HLO$ADMN HLO$ADMS HLO$ALLC HLO$BCHJ
    HLO$BCPY HLO$BDSN HLO$BGDG HLO$BJBC HLO$BJBN HLO$BMSD HLO$BMSG
    HLO$BPRD HLO$BRST HLO$BULD HLO$BULJ HLO$BUT2 HLO$BUTA HLO$BUTB
    HLO$BUTC HLO$BUTD HLO$BUTE HLO$BUTG HLO$BUTH HLO$BUTI HLO$BUTJ
    HLO$BUTK HLO$BUTM HLO$BUTP HLO$BUTQ HLO$BUTR HLO$BUTS HLO$BUTT
    HLO$BUTU HLO$BUTV HLO$BUTX HLO$BUTZ HLO$CALL HLO$CHAR HLO$CRID
    HLO$CTCM HLO$DCVT HLO$DLOG HLO$DSET HLO$EDIT HLO$EDT2 HLO$EDTI
    HLO$EDTT HLO$EQRY HLO$EXPB HLO$EXPD HLO$EXPF HLO$FCOL HLO$IMPD
    HLO$IMPE HLO$IMPF HLO$INFO HLO$JBRK HLO$JOBD HLO$JOBR HLO$JOPT
    HLO$JOTM HLO$JOVR HLO$JPRC HLO$JPRD HLO$JPRJ HLO$JPRU HLO$LJBO
    HLO$LOBJ HLO$LPRD HLO$LSTP HLO$OINC HLO$OPRC HLO$OPRD HLO$OPRE
    

Fix information

  • Fixed component name

    IDAA LOADER ZOS

  • Fixed component ID

    5639OLA00

Applicable component levels

  • R210 PSY UI79494

       UP22/03/15 P F203

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":"LOB10","label":"Data and AI"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSZJXP","label":"DB2 Tools for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.1.0"}]

Document Information

Modified date:
02 April 2022