APAR status

  • Closed as program error.

Error description

  • See problem summary
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * GDPS Metro                                                   *
    * GDPS Global - GM                                             *
    * GDPS Global - XRC                                            *
    * keywords: GDPSMETRO/K GDPSXRC/K GDPSGM/K GDPSLCPMGR/K        *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * GDPS METRO AND GLOBAL FIX PACKAGE 2022-01                    *
    *                                                              *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    Problems addressed in GDPS Metro, GDPS GM, and GDPS XRC:
    - In the GEOGROUP management panel, if the user has more than
    one group defined, the refresh action will not occur in some
    partners (4.3, 4.4)
    - A CPC suspend or resume using the panel action on VPCPCOPS is
    causing GDPS to incorrectly mark the monitor for this CPC as
    running.  This causes GDPS to issue GEO929W HMC AUTOMATION
    INTERFACE MONITORING SKIPPED for each monitor1 execution. (4.4,
    4.5)
    - During GDPS initialization, if the BCPii session to the local
    SE is suspended, GDPS will report the CPC status as 'UNKNOWN' on
    panel VPCPCOPS and this status will remain UNKNOWN even after
    the connection is resumed. (4.4, 4.5)
    
    Problem addressed in GDPS Metro and GDPS XRC:
    - When &GDPSMODE = NO_DASD (for Metro) or TEST, TEST_FC1, or
    TEST_FC2 (for MZGM4SITE) the Metro GDPS Environment Information
    panel VPCPSTA1 does not display GDPS-lvl and MT status
    correctly. (4.4)
    
    Problem addressed in GDPS Metro and GDPS GM:
    - In a multiple consistency group configuration, a disk
    subsystem may have have duplicate entries in the Disk Subsystem
    List panel (VPCPDLST) panel. (4.3, 4.4)
    
    Problems addressed in GDPS Metro only:
    - DASD configuration information is lost if an unplanned event
    (like HyperSwap) occurs, or planned action is initiated by one
    user while another user is attempting to load a configuration
    from the VPCECOMM panel.(4.3, 4.4)
    - Text truncated on GDPS Metro Config Management help panel
    VPCPHCGR. (4.3, 4.4)
    - User is prevented from removing devices in an external LCP
    Manager environment where the candidate devices are cascaded
    from an MGMnSITE solution.
    - When a GDPS K-sys is IPLed and takes the master role, if there
    is an outstanding GEO2669A, this prompt is lost during the new
    master initialization. (4.3, 4.4, 4.5)
    - Following a freeze event in a PPRCFAILURE=STOP environment,
    the primary volumes are soft fenced. The first attempt at
    executing START SECONDARY following the freeze fails and
    presents a GEO2621E and plan 909 is reported in the GEO2618I
    message block indicating that the primary volumes are still Soft
    Fenced. Re-running START SECONDARY will refresh the data and
    successfully restart replication. (4.3, 4.4)
    - START SECONDARY does not detect presence of Outboard Copy
    Inhibit on PPRC secondary volumes. With this PTF, it is detected
    and reported with plan 915 in the GEO2618I message block. (4.3,
    4.4)
    - GDPS incorrectly allows a Standard action to run when a
    GEO2669A failure notification is active. (4.3, 4.4)
    - START SECONDARY ends with RC=8 when it is unable to restore
    relationships which are in the following state:
    Pri-Sus(10)->Sec-(Any-state). These relationships are flagged
    with plan 999 as reported in the GEO2618I message block
    indicating 'A non-restorable relationship was found'. They will
    now be correctly handled by a new plan 17. (4.3, 4.4)
    - Corrected 'SENSENOT PROVIDED' typo in GEO399E message when AOM
    I/O ERROR RC:0008 RSN:0028 occurs. (4.3, 4.4)
    - In START SECONDARY, the combination Pri-Pnd->Pri-Sus(n)
    replication states is currently not recognized as restoreable.
    This PTF now recognizes this combination and will perform
    restore plan 9. (4.4)
    - In configurations with multiple consistency groups, Monitor3
    does not perform Soft Fence checking for FBA consistency groups
    (4.3, 4.4)
    
    Problems addressed in GDPS Metro HyperSwap Manager only:
    - Options are not correctly propagated to the other system(s)
    following a REFRESH OPTIONS action. (4.3, 4.4)
    

Problem conclusion

  • This PTF fixes the reported problems.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH43016

  • Reported component name

    GDPS

  • Reported component ID

    694235B00

  • Reported release

    420

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    YesSpecatt / Pervasive / Xsystem

  • Submitted date

    2021-12-23

  • Closed date

    2022-04-28

  • Last modified date

    2022-05-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI80346 UI80347

Modules/Macros

  • VPCETDAS VPCCMCPC VPCESYSM VPCEGEO1 VPCEBCPO VPCPHRI1 VPCESSEX
    VPCESTA1 VPCETINI VPCEITGO VPCESSCR VPCESTD1 VPCES    VPCCDEFO
    VPCPHCGR VPCEDLST VPCEXMVA GEOLABEL VPCEMON3
    

Fix information

  • Fixed component name

    GDPS

  • Fixed component ID

    694235B00

Applicable component levels

  • R430 PSY UI80346

       UP22/04/29 P F204  

  • R440 PSY UI80347

       UP22/04/29 P F204  

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M"},"Platform":[{"code":"PF054","label":"z\/OS"}],"Version":"420"}]

Document Information

Modified date: