A fix is available
APAR status
Closed as new function.
Error description
OSAM Encryption support of IC2 IC, Advanced IC of HPIC, and UIC process of DRF.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All IMS Recovery Solution Pack for z/OS * * Version 2 Release 1 ( FMID=HAHM210 ) * * IMS Database Recovery Facility users. * **************************************************************** * PROBLEM DESCRIPTION: This APAR enables IMS Database Recovery * * Facility to support OSAM encryption of * * IC2 IC, Advanced IC of HPIC, and UIC * * process. * **************************************************************** * RECOMMENDATION: INSTALL CORRECTIVE SERVICE FOR APAR/PTF * **************************************************************** IMS Database Recovery Facility provides the following support for OSAM encryption. IMS Database Recovery Facility supports the z/OS data set encryption for the IMS OSAM database also when using user-image copies, IC2, SAMEDS ICs, or FlashCopies. The PTF for the following IMS APAR is required to use the new functions: - PH27729: IMS Version 15 If you want to create a new image copy dataset for an OSAM encrypted database in DRF, the PTF for the following APAR is required: - PH31513: IMS HP Image Copy for z/OS Version 4 Release 2 If you want to do hash pointer checking in DRF, the PTF for the following APAR is required: - PH24727: IMS HP Pointer Checker for z/OS Version 3 Release 1 Otherwise, it causes the following symptoms: - IMS HP Pointer Checker (HPPC) exits with a number of unexpected error messages about the OSAM encrypted database. - Incorrect values for physical blocks per track are reported in the HPPC validation report. Therefore, if this APAR is not applicable, run DRF with hash pointer checking disabled for recovered databases (without specifying the PC keyword in the ADD command).
Problem conclusion
IMSOSAMLDS/K
Temporary fix
Comments
APAR Information
APAR number
PH42957
Reported component name
IMS RCVR SOLUTN
Reported component ID
5655V8600
Reported release
210
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
YesSpecatt / New Function / Xsystem
Submitted date
2021-12-20
Closed date
2022-01-13
Last modified date
2024-12-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI78903
Modules/Macros
FRXBDMG0 FRXIVSM0 FRXRIOIN
Fix information
Fixed component name
IMS RCVR SOLUTN
Fixed component ID
5655V8600
Applicable component levels
R210 PSY UI78903
UP22/01/15 P F201
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU011","label":"Systems - zSystems software"},"Product":{"code":"SG19M"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"210"}]
Document Information
Modified date: