IBM Support

PH42921: UNABLE TO BLOCK IP ENDING IN 255 IF 0 IS BLOCKED

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Unable to use NETSTAT BLOCK if IP address ending in .255 if the
    same IP ending in .0 is also blocked.
    

Local fix

  • N/A
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All z/VM users of the NETSTAT BLOCK and      *
    *                 NETSTAT FILTER command.                      *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    ****************************************************************
    * RECOMMENDATION: APPLY PTF                                    *
    ****************************************************************
    When issuing a NETSTAT BLOCK command,
    user is unable to block an address
    ending in 255 if an address ending in
    0 is already blocked and vice versa.
    

Problem conclusion

  • The NETSTAT BLOCK command has been updated to allow addresses
    ending in 255 when addresses ending in 0 are already blocked or
    vice versa.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH42921

  • Reported component name

    TCP/IP FOR Z/VM

  • Reported component ID

    5735FAL00

  • Reported release

    720

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2021-12-20

  • Closed date

    2022-01-05

  • Last modified date

    2022-01-12

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI78817 UI78818

Modules/Macros

  • TCPARSE
    

Fix information

  • Fixed component name

    TCP/IP FOR Z/VM

  • Fixed component ID

    5735FAL00

Applicable component levels

  • R710 PSY UI78817

       UP22/01/12 I 1000

  • R720 PSY UI78818

       UP22/01/12 I 1000

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU029","label":"Software"},"Product":{"code":"SG27M","label":"APARs - z\/VM Environment"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"720","Line of Business":{"code":"LOB16","label":"Mainframe HW"}}]

Document Information

Modified date:
27 January 2025