Fixes are available
APAR status
Closed as program error.
Error description
If a test script contains multiple image synchronizations, it was observed that intermittently random ones report "red" when observed on the Citrix Monitoring Panel. The expected images do appear to be delivered to the screen as per visual examinations and thus shouldn't have been a failure. Also, the playback doesn't have any Image Synchronization failures reported in the Statistical Report and if there aren't any other legitimate failures, show as 100% successful. When this failure occurs, if the image synchronization is defined to stop a response time measurement, the corresponding response time is logged as high at nearly 30 seconds most of the time thereby throwing off the average measurements. A NullPointerException is reported in the Problem Determination logs where the Image Synchronization failure should have been logged. The error reported is: "RPIC0003E exception raised while memorizing expected event java.lang.NullPointerException".
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * RPT Users * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * ****************************************************************
Problem conclusion
Fixed
Temporary fix
Comments
APAR Information
APAR number
PH41805
Reported component name
PERF TESTER WIN
Reported component ID
5724J9601
Reported release
A21
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2021-11-02
Closed date
2022-10-20
Last modified date
2022-10-20
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
PERF TESTER WIN
Fixed component ID
5724J9601
Applicable component levels
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSMMM5","label":"Rational Performance Tester"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"A21","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
20 October 2022