A fix is available
APAR status
Closed as program error.
Error description
When running QCF batch, module IQCCCVC0 gets storage in ECSA for an SPST and does not release it. This results in ECSA consumption that is not resolved until IMS is recycled. keywords: increasing utilization storage filling up
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All IBM IMS Queue Control Facility for z/OS * * Version 3 Release 2 (FMID=H0GN320) users. * **************************************************************** * PROBLEM DESCRIPTION: When running QCF batch, module IQCCCVC0 * * gets storage in ECSA for an SPST and * * does not release it. This results in * * ECSA consumption that is not resolved * * until IMS is recycled. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** When running QCF batch, QCF issues the DFSCWU FUNC=CWU macro to generate a new Work Unit. This macro creates some control blocks (ex. PST) in ECSA. QCF does not release the Work Unit at the termination of the task, so the Work Unit waits as inactive. Therefore, every time running QCF batch, the waiting Work Unit increases and the ECSA grows.
Problem conclusion
QCF has been changed to issue the DFSCWU FUNC=DRWU macro. The Work Unit is released by the dispatcher at the termination of the task.
Temporary fix
Comments
APAR Information
APAR number
PH41571
Reported component name
IMS QUEUE CNTL
Reported component ID
5697E9900
Reported release
320
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2021-10-25
Closed date
2021-11-05
Last modified date
2021-12-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI77948
Modules/Macros
IQCCSCHE IQCCSCHF
Fix information
Fixed component name
IMS QUEUE CNTL
Fixed component ID
5697E9900
Applicable component levels
R320 PSY UI77948
UP21/11/06 P F111
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":"LOB10","label":"Data and AI"},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX8A6","label":"IMS Tools"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"320"}]
Document Information
Modified date: