A fix is available
APAR status
Closed as program error.
Error description
If a user uses line command AL and changes an attribute (for example, VALIDPROC) on panel ADB21TA ('Alter Table'), but then finds a mistake and attempts to correct it without leaving the panel, the correction is not processed properly. As a result, the user may receive an SQLCODE = -601 error. For example: THE NAME (VERSION OR VOLUME SERIAL NUMBER) OF THE OBJECT TO BE DEFINED OR THE TARGET OF A RENAME STATEMENT IS IDENTICAL TO THE EXISTING NAME (VERSION OR VOLUME SERIAL NUMBER) XXXXX OF THE OBJECT TYPE VALIDPROC Furthermore, if the customer exits the panel and then re-enters it, the attribute still displays the original, uncorrected value. Keyword: SQLCODEN601
Local fix
Turn on the definition SQL prompt on panel ADB2PRMT by executing the 'P' command on the main menu and then the 'PR' command on panel ADB2P, and setting 'Definition SQL' to YES. This should allow the user to do more than one alter on the panel.
Problem summary
**************************************************************** * USERS AFFECTED: Users of Db2 Administration Tool for z/OS * **************************************************************** * PROBLEM DESCRIPTION: While changing a table attribute twice * * on panel ADB21TA, the second change * * does not process. * **************************************************************** On panel ADB21TA, the user issues an AL line command on a table to change attributes and changes the wrong attribute. While attempting to change the value back, the second change is not processed. This problem occurs only when the 'Definition SQL' prompt on panel ADB2PRMT is set to NO. This problem also occurs on panel ADB21TAA.
Problem conclusion
The problems have been resolved.
Temporary fix
Comments
APAR Information
APAR number
PH41486
Reported component name
DB2 ADMIN TOOL
Reported component ID
568851500
Reported release
C10
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2021-10-21
Closed date
2022-01-20
Last modified date
2022-02-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI78994
Modules/Macros
ADB21TA ADB21TAA
Fix information
Fixed component name
DB2 ADMIN TOOL
Fixed component ID
568851500
Applicable component levels
RC10 PSY UI78994