IBM Support

PH41454: IF A SYNTAX ERROR IS COMMITTED WHEN CODING A CONTROL STATEMENT, ALL CONFIGURATION PARAMETERS WILL BE DEFAULTED.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • If a configuration control statement in a DD:CHCCNTRL data set
    member is coded with a syntax error, then all coded
    configuration keywords for the configuration control statement
    in that data set member will be ignored, and the default values
    for the ignored keywords will be used instead.
    

Local fix

  • Correct any syntax errors in the configuration members.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of InfoSphere CDC for z/OS             *
    ****************************************************************
    * PROBLEM DESCRIPTION: If message CHC9744E is issued due to a  *
    *                      configuration control statement syntax  *
    *                      error that appears as a premature end   *
    *                      of the control statement, all keywords  *
    *                      on the control statement will be set to *
    *                      their defaults, including those that    *
    *                      are not incorrectly coded.              *
    ****************************************************************
    A control statement syntax error can cause all configuration
    parameters on the control statement to be set to default values.
    

Problem conclusion

  • The configuration parser logic has been improved to continue
    loading the valid configurations when unexpected end of file
    issue occurs. The related messages have been reworded to be less
    confusing.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH41454

  • Reported component name

    INFO SRVR CDC Z

  • Reported component ID

    5655U7600

  • Reported release

    A21

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2021-10-20

  • Closed date

    2021-11-14

  • Last modified date

    2021-12-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI78062

Modules/Macros

  • CHCCUTIL CHCMBARA CHCMBCHS CHCMBCHT CHCMBDAN CHCMBDES CHCMBDEU
    CHCMBELL CHCMBENG CHCMBENP CHCMBENU CHCMBESP CHCMBFIN CHCMBFRA
    CHCMBFRB CHCMBFRC CHCMBFRS CHCMBHEB CHCMBISL CHCMBITA CHCMBITS
    CHCMBJPN CHCMBKOR CHCMBNLB CHCMBNLD CHCMBNOR CHCMBPTB CHCMBPTG
    CHCMBRMS CHCMBRUS CHCMBSVE CHCMBTHA CHCMBTRK
    

Fix information

  • Fixed component name

    INFO SRVR CDC Z

  • Fixed component ID

    5655U7600

Applicable component levels

  • RA21 PSY UI78062

       UP21/11/24 P F111

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":"LOB10","label":"Data and AI"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSTVMA","label":"InfoSphere Data Replication for DB2 for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"10.2.1"}]

Document Information

Modified date:
02 December 2021