IBM Support

PH41401: DB2 CLONING TOOL 3.2 – OCTOBER PTF

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • This release contains the following bug fixes:
    1. Application cloning target job ends with log apply-related
    errors because of an incorrect log apply start point selection
    2. When application cloning target log apply modifies only
    extension data sets of a nonpartitioned object, its indexes are
    not rebuilt
    3. Application cloning target job does not check log
    apply-related DDs
    4. A space between catalog name and volser in the USERCATALOGS*
    keyword causes subsystem copy COPY command to fail with
    CKZ02058E message
    5. RENAME hangs if a value of 0 is specified for MAX-TASKS or
    MAX_RENAME_TASKS
    6. Application cloning source job with DATA-MOVER PGM(SRCIMCPY)
    and REUSE(Y) fails with CKZ1559E
    7. Several internal bugs are fixed
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of Db2 Cloning Tool for z/OS           *
    ****************************************************************
    * PROBLEM DESCRIPTION: 1. Application cloning target job ends  *
    *                      with log apply-related errors because   *
    *                      of an incorrect log apply start point   *
    *                      selection                               *
    *                      2. When application cloning target log  *
    *                      apply modifies only extension data sets *
    *                      of a nonpartitioned object, its indexes *
    *                      are not rebuilt                         *
    *                      3. Application cloning target job does  *
    *                      not check log apply-related DDs         *
    *                      4. A space between catalog name and     *
    *                      volser in the USERCATALOGS* keyword     *
    *                      causes subsystem copy COPY command to   *
    *                      fail with CKZ02058E message             *
    *                      5. RENAME hangs if a value of 0 is      *
    *                      specified for MAX-TASKS or              *
    *                      MAX_RENAME_TASKS                        *
    *                      6. Several internal bugs are fixed      *
    ****************************************************************
    * RECOMMENDATION: Apply the PTF                                *
    ****************************************************************
    1. Application cloning target job ends with log apply-related
    errors because of an incorrect log apply start point selection
    2. When application cloning target log apply modifies only
    extension data sets of a nonpartitioned object, its indexes are
    not rebuilt
    3. Application cloning target job does not check log
    apply-related DDs
    4. A space between catalog name and volser in the USERCATALOGS*
    keyword causes subsystem copy COPY command to fail with
    CKZ02058E message
    5. RENAME hangs if a value of 0 is specified for MAX-TASKS or
    MAX_RENAME_TASKS
    6. Several internal bugs are fixed
    

Problem conclusion

  • Apply the PTF
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH41401

  • Reported component name

    DB2 CLONING TOO

  • Reported component ID

    5655N1000

  • Reported release

    320

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2021-10-18

  • Closed date

    2021-11-01

  • Last modified date

    2021-12-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI77875

Modules/Macros

  • CKZ#A001 CKZ#ACIR CKZ#ACIW CKZ#ACON CKZ#ACRD CKZ#ACUP CKZ#ADIS
    CKZ#ADSC CKZ#AEXT CKZ#AFMT CKZ#AFRR CKZ#ALLO CKZ#AMIN CKZ#ASYS
    CKZ#AUMX CKZ#AUTO CKZ#BIND CKZ#CARD CKZ#CHKR CKZ#CL   CKZ#CL64
    CKZ#CL7  CKZ#CL8  CKZ#CLLS CKZ#CMTS CKZ#CN64 CKZ#CNTL CKZ#CNVT
    CKZ#CPM  CKZ#CPNT CKZ#CPOL CKZ#DB2V CKZ#DSAF CKZ#DSPL CKZ#DSQL
    CKZ#DYNL CKZ#ENCR CKZ#ENQS CKZ#ENVF CKZ#EPRI CKZ#FCPY CKZ#ICAI
    CKZ#ICAL CKZ#ICCC CKZ#ICCI CKZ#IDCF CKZ#IDSA CKZ#IERR CKZ#IHSA
    CKZ#IKPL CKZ#IKPN CKZ#ILGP CKZ#ILRA CKZ#ILRS CKZ#ILSA CKZ#INIT
    CKZ#IOPF CKZ#IPIE CKZ#IPPB CKZ#IPPC CKZ#IPPD CKZ#IPPH CKZ#IPPL
    CKZ#IPPN CKZ#IPPS CKZ#IRPL CKZ#ISNA CKZ#JPRI CKZ#JU64 CKZ#JUST
    CKZ#LGAA CKZ#LGAC CKZ#LGAF CKZ#LGAI CKZ#LGAP CKZ#LOGR CKZ#LRD6
    CKZ#MAIN CKZ#MDRV CKZ#MLOG CKZ#MMGR CKZ#MPRI CKZ#MREP CKZ#MTIO
    CKZ#NREC CKZ#OPRI CKZ#OS   CKZ#PRF5 CKZ#PRNG CKZ#QSAM CKZ#RANG
    CKZ#RESM CKZ#RH   CKZ#RH10 CKZ#RM24 CKZ#RPRP CKZ#RUNT CKZ#SQL2
    CKZ#SQLC CKZ#STAT CKZ#STCK CKZ#STMT CKZ#SUBD CKZ#SUBS CKZ#SUBX
    CKZ#SYSC CKZ#TB   CKZ#TB7  CKZ#TB8  CKZ#TP   CKZ#TP10 CKZ#TSS
    CKZ#TSSA CKZ#TUTL CKZ#UPRI CKZ#URDT CKZ#UTLB CKZ#UTLC CKZ#UTLS
    CKZ#UTOP CKZ#VERS CKZ#VSM  CKZ#WRIT CKZ#XMLI CKZ#XMLJ CKZ#XMLS
    CKZ$ACCS CKZ$BDSN CKZ$BMSG CKZ$BOOT CKZ$BUTJ CKZ$CAF  CKZ$CAFA
    CKZ$CALL CKZ$CTCM CKZ$DCMD CKZ$DCVT CKZ$DS   CKZ$DSN  CKZ$ESTA
    CKZ$INFO CKZ$PRFD CKZ$PRFR CKZ$SMSG CKZ$SPRM CKZ$SQL2 CKZ$SQLC
    CKZ$SSCT CKZ$TOK  CKZ$TSOC CKZ$URDT CKZ$ZPAR CKZ00020 CKZ00100
    CKZ00500 CKZ00501 CKZ00502 CKZ00505 CKZ00506 CKZ00510 CKZ00520
    CKZ00524 CKZ00525 CKZ00526 CKZ00527 CKZ00528 CKZ00529 CKZ00530
    CKZ00532 CKZ00533 CKZ00534 CKZ00535 CKZ00536 CKZ00537 CKZ00538
    CKZ00539 CKZ00540 CKZ00541 CKZ00542 CKZ00543 CKZ00544 CKZ00545
    CKZ00546 CKZ00547 CKZ00548 CKZ00549 CKZ00550 CKZ00551 CKZ00552
    CKZ00553 CKZ00554 CKZ00555 CKZ00556 CKZ00560 CKZ00561 CKZ00562
    CKZ00563 CKZ00564 CKZ00565 CKZ00566 CKZ00567 CKZ00569 CKZ00573
    CKZ00574 CKZ00575 CKZ00600 CKZ00602 CKZ00610 CKZ00611 CKZ00612
    CKZ00613 CKZ00619 CKZ00620 CKZ00621 CKZ00622 CKZ00624 CKZ00631
    CKZ00640 CKZ00669 CKZ00670 CKZ00671 CKZ00672 CKZ00674 CKZ00677
    CKZ00680 CKZ00708 CKZ00709 CKZ00710 CKZ00711 CKZ00713 CKZ00714
    CKZ00715 CKZ00716 CKZ00717 CKZ00718 CKZ00720 CKZ00721 CKZ00722
    CKZ00723 CKZ00760 CKZ00761 CKZ00764 CKZ00765 CKZ00766 CKZ00768
    

Fix information

  • Fixed component name

    DB2 CLONING TOO

  • Fixed component ID

    5655N1000

Applicable component levels

  • R320 PSY UI77875

       UP21/11/02 P F111

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":"LOB10","label":"Data and AI"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSZJXP","label":"DB2 Tools for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.2.0"}]

Document Information

Modified date: