Error description

  • The MSU calculation for several tables uses PDT (PARTITION
    Dispatch Time) instead of EDT(EFFECTIVE dispatch time). This
    results in an inaccurate MSU consumed calculation.
    
    NUM_CONSUMED_MSU = [SUM(SMF70PDT)*3600*16] / [SMF70PCA *
    SMF70INT * 1000]
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All IBM Z Decision Support (IZDS) and        *
    *                 IBM Z Performance and Capacity Analytics     *
    *                 (IZPCA) users who use the following          *
    *                 components:                                  *
    *                 z/OS Performance Management (MVSPM),         *
    *                 z/OS System (MVS) and                        *
    *                 Key Performance Metrics - z/OS (KPMZOS).     *
    ****************************************************************
    * PROBLEM DESCRIPTION: The calculated MSU consumption is       *
    *                      using SMF70PDT (Partition Dispatch      *
    *                      Time) instead of SMF70EDT (Effective    *
    *                      Dispatch Time).                         *
    ****************************************************************
    * RECOMMENDATION: Apply the provided PTF(s).                   *
    ****************************************************************
    Calculated MSUs consumed are based on
    logical processor dispatch time, instead of
    logical processor effective dispatch
    time. The difference between PDT & EDT (LPAR Management Time)
    is not taken into account by SCRT reporting.
    

Problem conclusion

  • The calculation of the number of consumed MSUs is changed to
    use logical processor effective dispatch time (SMF70EDT),
    instead of logical processor dispatch time (SMF70PDT) to
    align with SCRT reporting.
    
    This impacts the following column NUM_CONSUMED_MSU on the
    following tables and views:
    KPMZ_LPAR_H
    KPMZ_LPAR_HV
    KPMZ_LPAR_T
    KPMZ_LPAR_TV
    MVS_LPAR_D
    MVS_LPAR_DV
    MVS_LPAR_M
    MVS_LPAR_MV
    MVSPM_LPAR_CG_HV
    MVSPM_LPAR_H
    MVSPM_LPAR_HV
    MVSPM_LPAR_MSU_T
    MVSPM_LPAR_RMF_HV
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH41200

  • Reported component name

    TDS FOR Z/OS

  • Reported component ID

    569510100

  • Reported release

    C01

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2021-10-08

  • Closed date

    2022-01-27

  • Last modified date

    2022-02-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI79019 UI79020

Modules/Macros

  • DRLTKZLP DRLTMPLP DRLTMVLP DRLTPMSU
    

Fix information

  • Fixed component name

    TDS FOR Z/OS

  • Fixed component ID

    569510100

Applicable component levels

  • R9A0 PSY UI79020

       UP22/01/29 P F201

  • RCA0 PSY UI79019

       UP22/01/29 P F201

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":"LOB35","label":"Mainframe SW"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS2DUM","label":"IBM Z Decision Support"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"C01"}]

Document Information

Modified date:
02 February 2022