Error description

  • The IMS logger Exit routine of Sysplex Manager (GJEIFLGF) can
    cause ABEND0C4 in MRTRCHKX during IMS shutdown.          S0C4
    

Local fix

  • N/A
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of IMS Sysplex manager.            *
    ****************************************************************
    * PROBLEM DESCRIPTION: IMS logger Exit routine of Sysplex      *
    *                      Manager (GJEIFLGF) can cause ABEND0C4   *
    *                      in MRTRCHKX during IMS shutdown.        *
    ****************************************************************
    * RECOMMENDATION: Apply the PTF that corrects this APAR.       *
    ****************************************************************
    IMS logger Exit routine of Sysplex Manager (GJEIFLGF) called
    DFSMRTR0 to issue a GJE2004I message during the IMS shutdown
    process. DFSMRTR0 treated a field at offset 0 in caller's save
    area as SAP address (Save Area Prefix address), but because
    Sysplex Manager obtained the save area with STORAGE OBTAIN
    without initializing it, the value of that field was indefinite
    improper value. This caused ABENDS0C4 in MRTRCHKX.
    

Problem conclusion

  • GJEIFLGF and GJEIIPMF have been modified to initialize for the
    work areas including save areas obtained by STORAGE OBTAIN.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH40839

  • Reported component name

    IMS SYSPLEX MGR

  • Reported component ID

    5655P0100

  • Reported release

    130

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2021-09-24

  • Closed date

    2021-10-15

  • Last modified date

    2021-11-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI77616

Modules/Macros

  • GJEIFLGE GJEIFLGF GJEIIPME GJEIIPMF
    

Fix information

  • Fixed component name

    IMS SYSPLEX MGR

  • Fixed component ID

    5655P0100