A fix is available
APAR status
Closed as program error.
Error description
CQCLOAD needs to be added to the ADHMSTR SAMPLIB member. The master doesn't stop without CQCLOAD.
Local fix
Workaround: adding hlq.SCQCLOAD to the STEPLIB of the master ADHMSTR
Problem summary
**************************************************************** * USERS AFFECTED: Users of IBM Security Guardium S-TAP for * * Db2 on z/OS * **************************************************************** * PROBLEM DESCRIPTION: CQCLOAD needs to be added to the * * ADHMSTR SAMPLIB member. The master * * doesn't stop without CQCLOAD. * **************************************************************** * RECOMMENDATION: Apply the PTF. * **************************************************************** CQCLOAD needs to be added to the ADHMSTR SAMPLIB member. The master doesn't stop without CQCLOAD.
Problem conclusion
CQCLOAD was added to SAMPLIB member ADHMSTR.
Temporary fix
Comments
APAR Information
APAR number
PH40754
Reported component name
SEC GUAR STAP D
Reported component ID
5655STP00
Reported release
A13
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2021-09-21
Closed date
2022-01-14
Last modified date
2022-02-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI78923
Modules/Macros
ADHMSTR
Fix information
Fixed component name
SEC GUAR STAP D
Fixed component ID
5655STP00
Applicable component levels
RA13 PSY UI78923
UP22/01/15 P F201
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":"LOB24","label":"Security Software"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSMPHH","label":"IBM Security Guardium"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"A13"}]
Document Information
Modified date: