Error description
APAR PH36777 added code to SIGYMAC(IGYCOPT) to recognize the problem when administrators incorrectly coded OPTION( ) instead of OPTION=( ) or coded an unknown compiler option. Administrators are getting confused because the *** MNOTE *** message says OPT=VALUE instead of OPTION=VALUE. They mistakenly think that there is a problem with the OPT (OPTIMIZE) compiler option. They also do not recognize that the list of invalid options is listed immediately below the message, in the assembler listing output for IGYCDOPT. The original error message produced by the MNOTE in the IGYCOPT macro was not clear enough and seemed to imply that there was a problem with the OPT compiler option, when it was actually referring to any compiler OPTION. The message also did not instruct the administrator to look for the badly formatted or unknown compiler options immediately following the MNOTE error message in the assembler listing.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All administrators of the z/OS Enterprise * * COBOL V6.3 Compiler who are planning to * * modify compiler option default values by * * building the IGYCDOPT program. * **************************************************************** * PROBLEM DESCRIPTION: APAR PH36777 added code to * * SIGYMAC(IGYCOPT) to recognize the * * problem when administrators incorrectly * * coded OPTION( ) instead of OPTION=( ), * * or coded an unknown compiler option. * * Administrators are getting confused * * because the message says OPT=VALUE * * instead of OPTION=VALUE, and * * mistakenly think that there is a * * problem with the OPT (OPTIMIZE) * * compiler option. They also do not * * recognize that the list of invalid * * options is listed immediately below the * * message, in the assembler listing * * output for igycdopt. * **************************************************************** * RECOMMENDATION: Apply the IBM provided PTF * **************************************************************** The original error message produced by the MNOTE in the IGYCOPT macro was not clear enough and seemed to imply that there was a problem with the OPT compiler option, when it was actually referring to any compiler OPTION. The message also did not instruct the administrator to look for the badly formatted or unknown compiler options to immediately follow the error message in the assembler listing.
Problem conclusion
The MNOTE error message produced when an incorrectly formatted or unknown compiler option is specified in the IGYCDOPT assembler file has been reworded to clearly identify the problem. It also now instructs the admin to look for the unknown or badly formatted options to immediately follow this message in the assembler listing.
Temporary fix
Comments
APAR Information
APAR number
PH40314
Reported component name
ENT COBOL FOR Z
Reported component ID
5655EC600
Reported release
630
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2021-09-01
Closed date
2021-09-27
Last modified date
2021-10-20
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
IGY8RWTU IGYCASMB IGYCCBE IGYCCCRT IGYCCICS IGYCCSRV IGYCDGEN IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4 IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8 IGYCJA$D IGYCJA$R IGYCLIBR IGYCLSTR IGYCLVL0 IGYCLVL1 IGYCLVL2 IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOB2E IGYCOPI IGYCOPT IGYCOSCN IGYCPGEN IGYCRCTL IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT IGYCSCAN IGYCSIMD IGYCUE$0 IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8 IGYCUE$D IGYCUE$R IGYCXREF IGYDRV IGYEQCWI IGYMSGE IGYMSGK IGYMSGT IGYQCBE IGYQSPLT IGYSIDE2 IGYZQEN6 IGYZQENU IGYZQJP6 IGYZQJPN
Fix information
Fixed component name
ENT COBOL FOR Z
Fixed component ID
5655EC600
Applicable component levels
R630 PSY UI77327
UP21/10/01 P F109
R631 PSY UI77328
UP21/10/01 P F109
R632 PSY UI77329
UP21/10/01 P F109
R63H PSY UI77330
UP21/10/01 P F109
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"630","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
12 December 2023