A fix is available
APAR status
Closed as program error.
Error description
Customer is using the OUTPUT Optim command to copy the contents of the Optim ISPF panel to SYSOUT, or a data set. The command executes correctly and produces the expected contents.However, the following ABEND may occur while exiting Optim: User abend 4,094 dec occurred processing command DSN USER COMPLETION CODE=4094 REASON CODE=00000018 TIME=15.16.27 SEQ=04847 CPU=0000 ASID=008F PSW AT TIME OF ERROR 078D1400 85BAF576 ILC 2 INTC 0D NO ACTIVE MODULE FOUND NAME=UNKNOWN DATA AT PSW 05BAF570 - 00181610 0A0DA7F4 001C1811 The above ABEND has only been observed on z/OS 2.4 systems.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All Optim users who utilize the OUTPUT * * command with various Optim ISPF panels on * * z/OS 2.4. * **************************************************************** * PROBLEM DESCRIPTION: Optim may produce an ABEND U4094. * **************************************************************** Optim may produce an ABEND U4094. This is caused by an incompatibility with z/OS 2.4.
Problem conclusion
This APAR will provide temporary relief for the ABEND until a permanent resolution has been determined.
Temporary fix
Comments
APAR Information
APAR number
PH40237
Reported component name
OPTIM MOVE FOR
Reported component ID
5655V0700
Reported release
B70
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2021-08-30
Closed date
2021-09-22
Last modified date
2021-10-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
FOP1OSFN FOP9APIM FOPCFPMN FOPHSTM FOPK11 FOPMAIN FOPMCMAI FOPMCOLA FOPMCOLP FOPMDPRC FOPMDXTR FOPMECMN FOPMEMAI FOPMMUNU FOPOMN FOPRS9 FOPZFMMN FOPZMAIN
Fix information
Fixed component name
OPTIM MOVE FOR
Fixed component ID
5655V0700
Applicable component levels
RB70 PSY UI77275
UP21/09/25 P F109
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M"},"Platform":[{"code":"PF054","label":"z\/OS"}],"Version":"B70"}]
Document Information
Modified date:
02 October 2021