Error description
October 2021 Maintenance Updates OMPE V540
Local fix
Apply PTF when available
Problem summary
**************************************************************** * USERS AFFECTED: Enhanced 3270 User Interface and TEP * * OMEGAMON Db2 Classic Near Term History * **************************************************************** * PROBLEM DESCRIPTION: (a) KOBUT016I message repeats every * * two minutes in TEMA when HUB TEMS * * is not available. * * * * (b) Unable to dynamically change SEQ * * data set parameters by using VARY * * command * **************************************************************** * RECOMMENDATION: Apply PTF * **************************************************************** (a) OMNIBASE module KOBUTL is issuing unnecessary messages. (b) The VARY command to read changed collection options from RKD2PAR members, e.g. /f IBMO2,F H2<ssid>,VARY OPTION=COPT<ssid>) is not changing the collection specifications for dynamic SEQ data set parameters.
Problem conclusion
(a) KD5PLEX and KD5AGENT load modules need to be rebuilt to pick up changes from OMNIBASE module KOBUTL. (b) Code was updated for the VARY command to work properly. Keywords: KD5PLEX KD5AGENT KOBUTL KOBUT016I NTH Collector VARY SEQ COPT
Temporary fix
Comments
×**** PE21/11/02 FIX IN ERROR. SEE APAR PH41814 FOR DESCRIPTION ×**** PE21/11/02 FIX IN ERROR. SEE APAR PH41814 FOR DESCRIPTION
APAR Information
APAR number
PH40091
Reported component name
OM XE DB2PE/PM
Reported component ID
5655OPE00
Reported release
540
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2021-08-25
Closed date
2021-10-25
Last modified date
2021-11-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI77805
Modules/Macros
DGORINEX KD5AGENT KDPPLEX KO2APCL2 KO2APCLK KO2APCLS KO2HWLMB
Fix information
Fixed component name
OM XE DB2PE/PM
Fixed component ID
5655OPE00
Applicable component levels
R540 PSY UI77805
UP21/10/28 P F110
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":"LOB10","label":"Data and AI"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSZJXP","label":"DB2 Tools for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.4.0"}]
Document Information
Modified date:
04 November 2021