IBM Support

PH39931: ABEND 0C4 WITH UTILITY DSLSDY

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • With SR2021, an abend 0C4 occurs when DSLSDY is run.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All MERVA ESA users.                         *
    ****************************************************************
    * PROBLEM DESCRIPTION: An abend 0C4 occurs with utility        *
    *                      DSLSDY when the third parameter has     *
    *                      the value 1 or 3. The parameter value   *
    *                      can be provided                         *
    *                      o In the job JCL in PARM.               *
    *                      o From the function table DSLFNTT.      *
    *                                                              *
    *                      An example for PARM in the job JCL is   *
    *                      PARM='L1PR0,E,1,KEEP'. Here value 1 is  *
    *                      specified directly.                     *
    *                                                              *
    *                      Another example is PARM='L1PR0,,,KEEP'. *
    *                      Here the second and third parameters    *
    *                      are omitted. Then the values specified  *
    *                      in the PRFORM parameter of the DSLFNTT  *
    *                      entry for the input queue L1PR0 are     *
    *                      taken. Assume that PRFORM=(E,3). Then   *
    *                      DSLSDY uses E as second and 3 as third  *
    *                      parameter.                              *
    ****************************************************************
    * RECOMMENDATION: This has been corrected. Now an abend 0C4    *
    *                 does no longer occur with DSLSDY.            *
    ****************************************************************
    

Problem conclusion

  • Now an abend 0C4 does no longer occur when DSLSDY is run with
    1 or 3 as third parameter. Moreover, the titles of the MCBs
    DWS760, DWS765, DWS775, DWS785, DWS786, and DWS787 have been
    adapted.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH39931

  • Reported component name

    MERVA ESA 4.1.0

  • Reported component ID

    5648B2900

  • Reported release

    410

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2021-08-18

  • Closed date

    2021-08-18

  • Last modified date

    2021-09-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI76820

Modules/Macros

  • DSLMS902 DSLNLS   DWSHMTB  DWSMTTTC
    

Fix information

  • Fixed component name

    MERVA ESA 4.1.0

  • Fixed component ID

    5648B2900

Applicable component levels

  • R410 PSY UI76820

       UP21/08/19 P F108

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.