A fix is available
APAR status
Closed as program error.
Error description
Advanced ACBGEN missed to search a specific assemble instructions when it found same strings in a module address. The utility should skip such module address.
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: IMS Library Integrity Utilities for z/OS, * * Version 2 Release 2 (FMID=H27P220) users * * who use the Advanced ACBGEN utility. * **************************************************************** * PROBLEM DESCRIPTION: The Advanced ACBGEN may cause * * unexpected hook error and end with * * ABEND U1014 when the following * * conditions meet: * * - The utility looks for an assemble * * instruction in DFSDLB30 module. * * - An address of DFSDLB30 which is * * expanded in the address space contains * * the same hex code that the utility is * * looking for. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** This APAR fixes the Advanced ACBGEN not to cause unexpected ABEND U1014 hook error. The Advanced ACBGEN uses several IMS modules and one of the module is the Block Builder, DFSDLBL0. The Advanced ACBGEN reduces the ACBGEN elapsed time by hooking IMS modules, looking for specific assemble instructions, and modifying those instructions to use own instructions. The Advanced ACBGEN uses several hex codes to look for these instructions. In some environment, an address of DFSDLB30 which is defined in DFSDLBL0 contains same hex codes the Advanced ACBGEN looks for. It should be skipped but the Advanced ACBGEN missed to skip. As a result of this, ABEND U1014 hook error occurred. The Advanced ACBGEN will skip such address by this APAR.
Problem conclusion
The following module has been changed to fix the problem: FABQHUK2
Temporary fix
Comments
APAR Information
APAR number
PH39786
Reported component name
IMS LIBR INTEG
Reported component ID
5655I4200
Reported release
220
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2021-08-11
Closed date
2021-08-25
Last modified date
2021-09-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI76908
Modules/Macros
FABQHUK2
Fix information
Fixed component name
IMS LIBR INTEG
Fixed component ID
5655I4200
Applicable component levels
R220 PSY UI76908
UP21/08/27 P F108
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":"LOB10","label":"Data and AI"},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX89N","label":"IMS Tools"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"220"}]
Document Information
Modified date:
02 September 2021