A fix is available
APAR status
Closed as program error.
Error description
MODID error for MOD ENTRY DSNGEPLC in SYSMOD UI65684 can occur when trying to apply UI65684 if Db2 12 for z/OS was ordered on or after December 11, 2020 and the user has HDBCC10 SMPMCS with REWORK 2020291 to SMP/E install the Db2 12 product.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * All users who ordered Db2 12 for z/OS on or * * after December 11, 2020 and have an HDBCC10 * * SMPMCS with REWORK 2020291 to SMP/E install * * the Db2 12 product * **************************************************************** * PROBLEM DESCRIPTION: * * After installing Db2 using * * the Db2 12 SUP tape, if the user * * attempts to apply UI65684, the * * APPLY may fail * **************************************************************** * RECOMMENDATION: * * Apply corrective PTF when available * **************************************************************** After installing Db2 using the Db2 product image with REWORK(2020291), if the user then attempts to apply UI65684, the following error may occur: GIM38201W THERE IS A MODID ERROR FOR MOD ENTRY DSNGEPLC IN SYSMOD UI65684. GIM31903I SYSMOD UI65684 DOES NOT SPECIFY UI71423 ON THE PRE OR SUP OPERAND. UI71423 IS THE RMID FOR MOD DSNGEPLC THAT IS CURRENTLY INSTALLED. GIM22601I APPLY PROCESSING FAILED FOR SYSMOD UI65684.
Problem conclusion
The problem is fixed by marking UI65684 PE and setting PH39468 as the fixing apar.
Temporary fix
Comments
APAR Information
APAR number
PH39468
Reported component name
DB2 OS/390 & Z/
Reported component ID
5740XYR00
Reported release
C10
Status
CLOSED PER
PE
YesPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2021-07-30
Closed date
2021-08-17
Last modified date
2021-09-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI76792
Modules/Macros
DSNGEPLC
Fix information
Fixed component name
DB2 OS/390 & Z/
Fixed component ID
5740XYR00
Applicable component levels
RC10 PSY UI76792
UP21/08/26 P F108 {
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":"LOB10","label":"Data and AI"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSEPEK","label":"DB2 for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"12.0"}]
Document Information
Modified date: