A fix is available
APAR status
Closed as program error.
Error description
The ICE267I/RSN=255 is being issued in the DFSORT JOBLOG when data is sorted in descending order, but the RSN=255 is not documented in the zSORT User's Guide. This combination is only issued when OPTION VERIFY is in effect and zSORT code is being executed. The OPTION VERIFY is used for sequence checking. ADDITIONAL KEYWORDS: SORT ACCELERATION z15 ZSORT/K MSGICE267I ICE053A MSGICE053A
Local fix
BYPASS/CIRCUMVENTION: //DFSPARM DD * OPTION NOVERIFY /*
Problem summary
**************************************************************** * USERS AFFECTED: * * All DFSORT users who sort using ZSORT with the following: * * 1. fixed length records (FLR) and * * 2. any of the key field is in descending order and * * 3. requesting runtime/installation VERIFY in effect * **************************************************************** * PROBLEM DESCRIPTION: * * The following messages were incorrectly issued even though * * the records were sorted correctly: * * ICE053A OUT OF SEQUENCE * * ICE267I 0 ZSORT ACCELERATOR PATH SELECTED RSN=255 * **************************************************************** * RECOMMENDATION: * ****************************************************************
Problem conclusion
DFSORT has been modified to correct the problem. KEYWORDS: ZSORT/K
Temporary fix
Comments
APAR Information
APAR number
PH39080
Reported component name
DATA FACILITY S
Reported component ID
5740SM105
Reported release
N00
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2021-07-19
Closed date
2022-07-18
Last modified date
2022-08-26
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI81522 UI81523 UI81524
Modules/Macros
ICEMTS
Fix information
Fixed component name
DATA FACILITY S
Fixed component ID
5740SM105
Applicable component levels
RN00 PSY UI81522
UP22/07/30 P F207
RP00 PSY UI81523
UP22/07/30 P F207
RQ00 PSY UI81524
UP22/07/30 P F207
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"N00"}]
Document Information
Modified date:
26 August 2022