A fix is available
APAR status
Closed as program error.
Error description
A CICS PA report ran against SMF110 records, showed the value for the 'Inbound Sockets characters sent count', SOCHROU1, was an invalidly large number in CICS TS 5.6. . Comparative example in CICS TS 5.4 to illustrate a good value in SOCHROU1: . Stop MaxTasks CurTasks Tran TaskNo SOChrOu1 Time 13:27:31.391 350 19 abc1 6731 559 13:27:41.107 350 15 def1 8034 651 . Example in CICS TS 5.6: . Stop MaxTasks CurTasks Tran TaskNo SOChrOu1 Time 13:45:47.627 350 14 abc1 75797 625252E3 13:45:48.942 350 14 def1 75891 625252E3 .
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All. * **************************************************************** * PROBLEM DESCRIPTION: Incorrect value in monitoring field * * SOCHROU1 and TRANSFER_COUNT in trace * * entries SO 0202 and SO 0802 . * **************************************************************** This problem presented as an invalid value in monitoring field SOCHROU1. This value is derived from TRANSFER_COUNT ( which is reported in SO 0202 and SO 0802 trace entries ) and may also contain an invalid value. Keywords: SO0202 SO0802 PH05297
Problem conclusion
DFHSOSE has been modified to correctly calculate TRANSFER_COUNT and in doing so, monitoring field SOCHROU1 will also be correct.
Temporary fix
Comments
×**** PE21/11/02 FIX IN ERROR. SEE APAR PH41778 FOR DESCRIPTION
APAR Information
APAR number
PH38881
Reported component name
CICS TS Z/OS V5
Reported component ID
5655Y0400
Reported release
300
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2021-07-12
Closed date
2021-10-27
Last modified date
2021-11-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI77832 PH41778
Modules/Macros
DFHSOSE
Fix information
Fixed component name
CICS TS Z/OS V5
Fixed component ID
5655Y0400
Applicable component levels
R300 PSY UI77832
UP21/10/28 P F110
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":"LOB35","label":"Mainframe SW"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.6"}]
Document Information
Modified date:
03 November 2021