PH38566: ABEND0C4-4 IN CQM#SSMN+X'4FBC'

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • This APAR addresses the following symptoms:
    - ABEND0C4-4 in CQM#SSMN+X'4FBC'
    - ABEND S0F8-0014 in CQCISMAX+X'57A'
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: USERS AFFECTED:                              *
    *                 Users of IBM Db2 Query Monitor for z/OS      *
    *                 Users of IBM Security Guardium S-TAP for     *
    *                 Db2 on z/OS                                  *
    ****************************************************************
    * PROBLEM DESCRIPTION: 1. ABEND0C4-4 in CQM#SSMN+X'4FBC'       *
    *                      2. ABEND S0F8-0014 in CQCISMAX+X'57A'   *
    ****************************************************************
    * RECOMMENDATION: APPLY the PTF.                               *
    ****************************************************************
    1. If Query Monitor and Guardium S-TAP for Db2 have different
    versions of shared modules and products are recycled several
    times, an ABEND0C4-4 may occur in module CQM#SSMN+X'4FBC'.
    2. Routine CQCISMAX in Query Monitor attempted to issue the
    CQM1205 message using WTO SVC. CQCISMAX did not check that it
    was working in SRB mode, so the WTO SVC abends with an S0F8.
    

Problem conclusion

  • 1. Logic was improved to detect shared modules versions
    mismatch more accurately.
    2. Logic was changed to use another form of WTO which works
    in both TCB and SRB modes.
    
    Search Keywords:
    ABEND 0C4 CQM#SSMN X'4FBC' RECYCLE
    ABEND S0F8-0014 CQCISMAX X'57A'
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH38566

  • Reported component name

    COMMON COLLECTO

  • Reported component ID

    5639OLC00

  • Reported release

    110

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2021-06-30

  • Closed date

    2021-09-09

  • Last modified date

    2021-10-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI77078

Modules/Macros

  • CQC#CQMA CQC#CSAL CQCISMAX CQCMALOX CQCMINST
    

Fix information

  • Fixed component name

    COMMON COLLECTO

  • Fixed component ID

    5639OLC00

Applicable component levels

  • R110 PSY UI77078

       UP21/09/16 P F109

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":"LOB10","label":"Data and AI"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSZJXP","label":"DB2 Tools for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"1.1.0"}]

Document Information

Modified date:
02 October 2021