Error description

  • The value of response time for the long running transactions
    exceeded 4 bytes limit after converting to STCK value for
    comparison.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of CICS PA V5.4                    *
    ****************************************************************
    * PROBLEM DESCRIPTION: The value of response time for long     *
    *                      running transactions exceeded the 4     *
    *                      byte limit.                             *
    ****************************************************************
    CICS tasks are not excluded from CICS PA reports when Selection
    Criteria are specified. This issue is caused by the value of
    response time for long running transactions exceeding their four
    byte limit after converting to a STCK value for comparison.
    

Problem conclusion

  • CICS PA Selection Criteria processing has been enhanced to
    support the large number comparison.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH38164

  • Reported component name

    CICS PERF ANALY

  • Reported component ID

    5655Y2300

  • Reported release

    540

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2021-06-16

  • Closed date

    2021-07-21

  • Last modified date

    2021-08-09

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI76387

Modules/Macros

  • CPAELECT CPAHDSEL
    

Fix information

  • Fixed component name

    CICS PERF ANALY

  • Fixed component ID

    5655Y2300

Applicable component levels

  • R540 PSY UI76387

       UP21/07/24 P F107

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":"LOB35","label":"Mainframe SW"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSPPU4","label":"CICS Performance Analyzer for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.4"}]

Document Information

Modified date:
10 August 2021