A fix is available
APAR status
Closed as program error.
Error description
HP Load does not close the DFSURWF1 data set if the WF1DSN control statement is specified. Therefore, HP Load can issue an HPSR0001I message and return RC=00 even if an ABENDSB37 occurs for the DFSURWF1 data set.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of IBM IMS High Performance Load * * for z/OS Version 2 Release 1 (FMID=H1IM210). * **************************************************************** * PROBLEM DESCRIPTION: HP Load does not close the DFSURWF1 * * data set if the WF1DSN control * * statement is specified. * * Therefore, HP Load can issue an * * HPSR0001I message and return RC=00 even * * if an ABENDSB37 occurs for the DFSURWF1 * * data set. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** HP Load does not close the DFSURWF1 data set if the WF1DSN control statement is specified. Therefore, HP Load can issue an HPSR0001I message and return RC=00 even if an ABENDSB37 occurs for the DFSURWF1 data set.
Problem conclusion
HP Load has been modified to close the DFSURWF1 data set even when the WF1DSN control statement is specified.
Temporary fix
Comments
APAR Information
APAR number
PH37976
Reported component name
IMS HP LOAD
Reported component ID
5655E0700
Reported release
210
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2021-06-08
Closed date
2021-06-24
Last modified date
2022-09-08
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI76048
Modules/Macros
HPSRDYF1 HPSRHDL2 HPSRHDL3 HPSRHDL4 HPSRHDL5 HPSRHDL7 HPSRHDL8 HPSRHDL9 HPSRHDLA HPSRHDLB
Fix information
Fixed component name
IMS HP LOAD
Fixed component ID
5655E0700
Applicable component levels
R210 PSY UI76048
UP21/06/26 P F106
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX89F","label":"IMS Tools"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.1.0"}]
Document Information
Modified date: