A fix is available
APAR status
Closed as program error.
Error description
If DB2 V12 is in use by IIDR CDC for z/OS and the Application Compatibility Level used to bind the IIDR CDC for z/OS plans is not at a DB2 V12 level, the Application Compatibility Level will be incorrectly determined to be 000. This can have negative repercussions if features of DB2 V12 are needed for proper operation.
Local fix
Rebind the IIDR CDC for z/OS plans with APPLCOMPAT(V12R1Mxxx), where xxx is a valid Function Level for DB2 V12.
Problem summary
**************************************************************** * USERS AFFECTED: Users of IIDR CDC for z/OS who are using DB2 * * V12. * **************************************************************** * PROBLEM DESCRIPTION: IIDR CDC for z/OS was developed to use * * the capabilities of the DB2 version to * * which is is connected. When operating * * IIDR CDC for z/OS with DB2 V12, if the * * APPLCOMPAT for any of the IIDR CDC for * * z/OS DB2 plans being used have been * * bound with a non-DB2 V12 APPLCOMPAT, * * aspects of the use of DB2 V12 may not * * operate properly or they may fail. * **************************************************************** IIDR CDC for z/OS needs to have its DB2 plans bound at an application compatibility level that matches the version of DB2 to which it is connected.
Problem conclusion
When operating with DB2 V12, IIDR CDC for z/OS and its utility programs will check the APPLCOMPAT level of the bound plans and not operate if they are not at a DB2 V12 level.
Temporary fix
Comments
APAR Information
APAR number
PH37953
Reported component name
INFO SRVR CDC Z
Reported component ID
5655U7600
Reported release
A21
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2021-06-08
Closed date
2021-08-23
Last modified date
2021-09-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI76883
Modules/Macros
CHCBNDPL CHCDB212 CHCDB2DL CHCMBARA CHCMBCHS CHCMBCHT CHCMBDAN CHCMBDES CHCMBDEU CHCMBELL CHCMBENG CHCMBENP CHCMBENU CHCMBESP CHCMBFIN CHCMBFRA CHCMBFRB CHCMBFRC CHCMBFRS CHCMBHEB CHCMBISL CHCMBITA CHCMBITS CHCMBJPN CHCMBKOR CHCMBNLB CHCMBNLD CHCMBNOR CHCMBPTB CHCMBPTG CHCMBRMS CHCMBRUS CHCMBSVE CHCMBTHA CHCMBTRK CHCMDMBD
Fix information
Fixed component name
INFO SRVR CDC Z
Fixed component ID
5655U7600
Applicable component levels
RA21 PSY UI76883
UP21/08/26 P F108
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":"LOB10","label":"Data and AI"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSTVMA","label":"InfoSphere Data Replication for DB2 for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"10.2.1"}]
Document Information
Modified date:
02 September 2021