IBM Support

PH37821: COLLECT OF IMS COMPONENT ABENDS WITH U0002. PROBLEM WAS CAUSED BY COLUMNS BEING DEFINED WITH INTEGER.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Collect of IMS component abends with U0002 and gives this error:
    DSNT408I SQLCODE = -302, ERROR:  THE VALUE OF INPUT VARIABLE OR
            PARAMET NUMBER 4 IS INVALID OR TOO LARGE FOR THE TARGET
            COLUMN OR THE VALUE
    DRL0000T The log collector run terminated abnormally. The
            DRLDUMP file contains detailed information.
    

Local fix

  • Made the following changes in member DRLTIMSS from the SDRLDEFS
    library.
    - Change column IMS_CHECKPOINT from SMALLINT to INTEGER. This
    column is repeated multiple times throughout DRLTIMSS.
    - Change the following columns from INTEGER to FLOAT:
    BUFFER_ALTER_CALLS
    PURGE_CALLS
    READ_IO_COUNT
    SCH_SMB_LOOKED_AT
    After you make those changes, please make sure you reinstall the
    component for the changes to take affect.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All TDSz/IZDS/IZPCA users of the IMS CSQ     *
    *                 Collect component.                           *
    ****************************************************************
    * PROBLEM DESCRIPTION: Message DSNT408I is issued when trying  *
    *                      to collect logs in IMS CSQ Collect.     *
    ****************************************************************
    * RECOMMENDATION: Apply the provided PTF(s).                   *
    ****************************************************************
    Message "DSNT408I SQLCODE = -302, ERROR: THE VALUE OF INPUT
    VARIABLE OR PARAMETER NUMBER 4 IS INVALID OR TOO LARGE FOR THE
    TARGET COLUMN OR THE TARGET VALUE" is issued when collecting
    logs using the IMS CSQ Collect component.
    

Problem conclusion

  • Alter the  definition of columns IMS_CHECKPOINT,
    BUFFER_ALTER_CALLS, PURGE_CALLS, SCH_SMB_LOOKED_AT and
    READ_IO_COUNT in tables IMS_CHKPT_IOSAM_T, IMS_CHKPT_POOLS_T,
    IMS_CHKPT_REGION_T, IMS_CHKPT_STATS_T and IMS_CHKPT_VSAM_T to
    prevent the DSNT408I message being issued.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH37821

  • Reported component name

    TDS FOR Z/OS

  • Reported component ID

    569510100

  • Reported release

    802

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2021-06-02

  • Closed date

    2021-06-30

  • Last modified date

    2021-07-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI76122 UI76123 UI76124

Modules/Macros

  • DRLTIMSS
    

Fix information

  • Fixed component name

    TDS FOR Z/OS

  • Fixed component ID

    569510100

Applicable component levels

  • R8A7 PSY UI76122

       UP21/07/01 P F106

  • R9A1 PSY UI76123

       UP21/07/01 P F106

  • RCA1 PSY UI76124

       UP21/07/01 P F106

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Type":"MASTER","Line of Business":{"code":"LOB35","label":"Mainframe SW"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS2DUM","label":"IBM Z Decision Support"},"Version":"All Versions"}]

Document Information

Modified date:
03 July 2021