Error description
Collect of IMS component abends with U0002 and gives this error: DSNT408I SQLCODE = -302, ERROR: THE VALUE OF INPUT VARIABLE OR PARAMET NUMBER 4 IS INVALID OR TOO LARGE FOR THE TARGET COLUMN OR THE VALUE DRL0000T The log collector run terminated abnormally. The DRLDUMP file contains detailed information.
Local fix
Made the following changes in member DRLTIMSS from the SDRLDEFS library. - Change column IMS_CHECKPOINT from SMALLINT to INTEGER. This column is repeated multiple times throughout DRLTIMSS. - Change the following columns from INTEGER to FLOAT: BUFFER_ALTER_CALLS PURGE_CALLS READ_IO_COUNT SCH_SMB_LOOKED_AT After you make those changes, please make sure you reinstall the component for the changes to take affect.
Problem summary
**************************************************************** * USERS AFFECTED: All TDSz/IZDS/IZPCA users of the IMS CSQ * * Collect component. * **************************************************************** * PROBLEM DESCRIPTION: Message DSNT408I is issued when trying * * to collect logs in IMS CSQ Collect. * **************************************************************** * RECOMMENDATION: Apply the provided PTF(s). * **************************************************************** Message "DSNT408I SQLCODE = -302, ERROR: THE VALUE OF INPUT VARIABLE OR PARAMETER NUMBER 4 IS INVALID OR TOO LARGE FOR THE TARGET COLUMN OR THE TARGET VALUE" is issued when collecting logs using the IMS CSQ Collect component.
Problem conclusion
Alter the definition of columns IMS_CHECKPOINT, BUFFER_ALTER_CALLS, PURGE_CALLS, SCH_SMB_LOOKED_AT and READ_IO_COUNT in tables IMS_CHKPT_IOSAM_T, IMS_CHKPT_POOLS_T, IMS_CHKPT_REGION_T, IMS_CHKPT_STATS_T and IMS_CHKPT_VSAM_T to prevent the DSNT408I message being issued.
Temporary fix
Comments
APAR Information
APAR number
PH37821
Reported component name
TDS FOR Z/OS
Reported component ID
569510100
Reported release
802
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2021-06-02
Closed date
2021-06-30
Last modified date
2021-07-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI76122 UI76123 UI76124
Modules/Macros
DRLTIMSS
Fix information
Fixed component name
TDS FOR Z/OS
Fixed component ID
569510100
Applicable component levels
R8A7 PSY UI76122
UP21/07/01 P F106
R9A1 PSY UI76123
UP21/07/01 P F106
RCA1 PSY UI76124
UP21/07/01 P F106