A fix is available
APAR status
Closed as program error.
Error description
Batch Accounting SAVE, incorrect data type of column RID_POOL_FAIL_NOTC
Local fix
Update HLQ.TKO2SAMP(DGOAUPDB) change DECIMAL(19,0) to DOUBLE PRECISION as the following: Before: ALTER TABLE DB2PMSACCT_GENERAL ADD COLUMN RID_POOL_FAIL_NOTC DECIMAL(19,0) NOT NULL WITH DEFAULT; After: ALTER TABLE DB2PMSACCT_GENERAL ADD COLUMN RID_POOL_FAIL_NOTC DOUBLE PRECISION NOT NULL WITH DEFAULT;
Problem summary
**************************************************************** * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2 PM * * users of component: * * - Batch report SAVE file / PDB * **************************************************************** * PROBLEM DESCRIPTION: Incorrect data type for column * * RID_POOL_FAIL_NOTC in module DGOAUPDB * **************************************************************** * RECOMMENDATION: Apply PTF. * **************************************************************** Incorrect data type in ALTER table DB2PMSACCT_GENERAL statement for column RID_POOL_FAIL_NOTC in module TKO2SAMP(DGOAUPDB)
Problem conclusion
Data type for RID_POOL_FAIL_NOTC in DGOAUPDB for table DB2PMSACCT_GENERAL changed from DECIMAL to DOUBLE PRECISION Keywords: OMPE BATCH DGOAUPDB PDB SAVE
Temporary fix
Comments
APAR Information
APAR number
PH37764
Reported component name
OM XE DB2PE/PM
Reported component ID
5655OPE00
Reported release
540
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2021-06-01
Closed date
2021-07-23
Last modified date
2021-08-09
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
DGOAUPDB DGOVMSTR FPEVDB2C FPEVDB2I KD5AGENT KO2ABROW KO2ACONB KO2APCL2 KO2APCLK KO2APCLS KO2APHLR KO2CCAFB KO2CDIN2 KO2CDINK KO2CDINS KO2CIF12 KO2CIF1K KO2CIF1S KO2CIF22 KO2CIF2K KO2CIF2S KO2CIF32 KO2CIF3K KO2CIF3S KO2CIF42 KO2CIF4K KO2CIF4S KO2CIF52 KO2CIF5K KO2CIF5S KO2CIF62 KO2CIF6K KO2CIF6S KO2CIF72 KO2CIF7K KO2CIF7S KO2CIF82 KO2CIF8K KO2CIF8S KO2CIF92 KO2CIF9K KO2CIF9S KO2CIFAB KO2CIFBB KO2CIFCB KO2CIFDB KO2CIFEB KO2CIFI2 KO2CIFIK KO2CIFIS KO2CMVSF KO2CTHB2 KO2CTHBK KO2CTHBS KO2CTHC2 KO2CTHCK KO2CTHCS KO2CTHD2 KO2CTHDK KO2CTHDS KO2CTHE2 KO2CTHEK KO2CTHES KO2CTHJ2 KO2CTHJK KO2CTHJS KO2CTHN2 KO2CTHNK KO2CTHNS KO2CTHO2 KO2CTHOK KO2CTHOS KO2DATA KO2HHQIB KO2HPR1B KO2HSQIB KO2HWLMB KO2INCAP KO2NDRVB KO2OAPIB KO2OCMCB KO2OENDB KO2OINTB KO2OQAL2 KO2OQALK KO2OQALS KO2ORCVB KO2OROUB KO2OTH8B KO2OTHGB KO2WTCA2 KO2WTCAK KO2WTCAS KO2XSY22 KO2XSY2K KO2XSY2S KO2XTHS2 KO2XTHSK KO2XTHSS KO2ZAPI KO2ZASY KO2ZIFI KO2ZRTO KO2ZSYN KO2ZTDC KO2ZTOP KO2ZTRK KO2ZWTO KO2ZZRM
Fix information
Fixed component name
OM XE DB2PE/PM
Fixed component ID
5655OPE00
Applicable component levels
R540 PSY UI76444
UP21/07/27 P F107
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":"LOB10","label":"Data and AI"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSZJXP","label":"DB2 Tools for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.4.0"}]
Document Information
Modified date:
10 August 2021