IBM Support

PH37623: MISSING MNTRI TRACE ENTRY POINTS

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Missing MNTRI trace entry points need to be added to
    CICS TS 5.3 and above.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All CICS Users.                              *
    ****************************************************************
    * PROBLEM DESCRIPTION: Missing trace points for 0D0D and 0D0C  *
    *                      in DFHMNTRI.                            *
    ****************************************************************
    DFHMNAC has unexpected error cases for DFHMNAC and DFHMPMO.
    These map to defined trace points for 0D0D and 0D0C in DFHMNCBS.
    
    However, these trace points are missing from DFHMNTRI the trace
    formatting routine.
    
    If an unexpected error case occurs in DFHMNAC, message
    DFHMN0002 is issued along with a system dump with
    exception trace X'0D0D' (or X'0D0C') in DFHMNAC.
    
    The trace shows - MN 0D0D ** POINT_ID NOT RECOGNIZED **
    (or - MN 0D0C ** POINT_ID NOT RECOGNIZED ** )
    

Problem conclusion

  • DFHMNTRI has been changed to add the missing trace points.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH37623

  • Reported component name

    CICS TS Z/OS V5

  • Reported component ID

    5655Y0400

  • Reported release

    000

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2021-05-27

  • Closed date

    2021-11-18

  • Last modified date

    2021-12-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI78151 UI78152 UI78153 UI78154

Modules/Macros

  • DFHMNTRI
    

Fix information

  • Fixed component name

    CICS TS Z/OS V5

  • Fixed component ID

    5655Y0400

Applicable component levels

  • R000 PSY UI78154

       UP21/11/20 P F111

  • R100 PSY UI78153

       UP21/11/19 P F111

  • R200 PSY UI78152

       UP21/11/19 P F111

  • R300 PSY UI78151

       UP21/11/19 P F111

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":"LOB35","label":"Mainframe SW"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.3"}]

Document Information

Modified date:
02 December 2021