IBM Support

PH37506: ABEND S0C4 RC=11 ON HLOMAINT (OFFSET=000002DA) WHEN THE SYNTAX PARM DOES NOT INCLUDE THE HLOID

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • ABEND S0C4 RC=11 on HLOMAINT when the syntax on the PARM is
    coded wrong and does not include the HLOID
    
    SYSTEM COMPLETION CODE=0C4  REASON CODE=00000011
     TIME=14.51.56  SEQ=57490  CPU=0000  ASID=00D2
     PSW AT TIME OF ERROR  078D1000   BFB002DA  ILC 4  INTC 11
       ACTIVE MODULE           ADDRESS=00000000_3FB00000
    OFFSET=000002DA
       NAME=HLOMAINT
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All Users                                    *
    ****************************************************************
    * PROBLEM DESCRIPTION: ABEND S0C4 RC=11 on HLOMAINT            *
    *                      (OFFSET=000002DA) when the syntax on    *
    *                      the PARM does not include the HLOID     *
    ****************************************************************
    ABEND S0C4 RC=11 on HLOMAINT (OFFSET=000002DA) when the syntax
    on the PARM does not include the HLOID
    

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    PH37506

  • Reported component name

    IDAA LOADER ZOS

  • Reported component ID

    5639OLA00

  • Reported release

    210

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2021-05-24

  • Closed date

    2021-07-20

  • Last modified date

    2021-08-09

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • HLOMAINT HLOSINIT HLOSTMGR HLOUCBAS HLOUCLBK HLOUNTOK
    

Fix information

  • Fixed component name

    IDAA LOADER ZOS

  • Fixed component ID

    5639OLA00

Applicable component levels

  • R210 PSY UI76383

       UP21/07/30 P F107

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":"LOB10","label":"Data and AI"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSZJXP","label":"DB2 Tools for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.1.0"}]

Document Information

Modified date: