A fix is available
APAR status
Closed as program error.
Error description
After an IPL if a rocket vector table does not exist already, then the loader job may fail with the following messages, IDI0002I Module HLOUHAL1, CSECT HAL15306, offset X'F6': Abend S0C1 (Operation Exception). SYSTEM COMPLETION CODE=0C1 REASON CODE=00000001 TIME=07.50.19 SEQ=15623 CPU=0000 ASID=01AE PSW AT TIME OF ERROR 478D1000 80000002 ILC 2 INTC 01 NO ACTIVE MODULE FOUND NAME=UNKNOWN
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All Users. * **************************************************************** * PROBLEM DESCRIPTION: S0C1 on Module HLOUHAL1, CSECT * * HAL15306, offset X'F6 * **************************************************************** S0C1 on Module HLOUHAL1, CSECT HAL15306, offset X'F6
Problem conclusion
Temporary fix
Comments
APAR Information
APAR number
PH37325
Reported component name
IDAA LOADER ZOS
Reported component ID
5639OLA00
Reported release
210
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2021-05-18
Closed date
2021-06-14
Last modified date
2021-07-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
HLO$INFO HLO2ADMF HLO2AREP HLO2BAKE HLO2BASE HLO2BLDJ HLO2BTAB HLO2CARD HLO2CONE HLO2DB2 HLO2DEVT HLO2DLCP HLO2DSSP HLO2DUAE HLO2EDPL HLO2ELDT HLO2ETCL HLO2ETDD HLO2EXCP HLO2EXTE HLO2GLOB HLO2GVAR HLO2HALE HLO2IMCE HLO2IMSG HLO2IOMS HLO2KSDS HLO2MAIN HLO2METL HLO2NDFN HLO2NPRO HLO2ORDS HLO2OTPO HLO2PRDM HLO2PRFD HLO2PRFL HLO2PRFR HLO2PRFX HLO2PRIM HLO2PROF HLO2PROP HLO2RECE HLO2RESL HLO2SAVH HLO2SCNV HLO2SIDS HLO2SKL HLO2SPRF HLO2STTC HLO2SUBS HLO2TBLB HLO2TBLS HLO2TEMP HLO2TIME HLO2TYPS HLO2ZPRM HLO7DGEN HLO7JMSP HLO7PARS HLO8ASG1 HLO8ASG2 HLO8ASG3 HLO8ASGN HLO8CNVT HLO8CONV HLOARCHK HLOARGSZ HLODEVT HLOISPF HLOMSGEN HLONEW HLOPANEL HLOPCONF HLOPROC HLORDB2S HLORPT HLOSDB2S HLOSINIT HLOSTCMD HLOSTDB2 HLOSTMGR HLOSTSES HLOUCBAS HLOUHLTP HLOUSTUB HLOXATCH HLOXATTA HLOXCONC HLOXDB2C HLOXDB2T HLOXDD HLOXDSCT HLOXEXCP HLOXODA HLOXOPDB HLOXPTA HLOXRACA HLOXSTRS HLOXWAIT HLOXWTA HLOXWTMA
Fix information
Fixed component name
IDAA LOADER ZOS
Fixed component ID
5639OLA00
Applicable component levels
R210 PSY UI75879
UP21/06/18 P F106
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Type":"MASTER","Line of Business":{"code":"","label":""},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSZJXP","label":""},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"All Versions"}]
Document Information
Modified date:
03 July 2021