A fix is available
APAR status
Closed as program error.
Error description
You are running module IGVDGNPP for the utility PRIMEPSA in CICS TS 5.6. The utility initialized lowcore storage with nonzero values to find potential references to uninitialized storage. In this case, CICS is creating the DFHJXSU URIMAP, and obtaining the current task userid. Atypically, the code is running as part of domain initialization, and not as a user task, so the domain transaction token references lowcore storage. While the code checks for a zero value in the first word of the token, the utility has populated that locale with nonzero values, leading to the ABENDs. KIXREVEAA
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All CICS users. * **************************************************************** * PROBLEM DESCRIPTION: CICS can abend 0C4 at startup in module * * DFHSJDM at offset 0xDAE if the z/OS * * debug utility IGVDGNPP is being used. * **************************************************************** If the z/OS debug utility IGVDGNPP is being used to prime unused areas of low core storage with values while CICS is started it is possible that CICS will abend with a 0C4 at offset 0xDAE in module DFHSJDM. A message like: "+DFHSJ0001 applid An abend (code 0C4/AKEA) has occurred at offset X'0DAE' in module DFHSJDM." will be seen in the job log just before the expected "Control is being given to CICS." message. A dump will be taken and another message should then be seen: "+DFHDM0105 applid Unsuccessful initialization of DFHSJ domain. CICS will terminate." Lastly, the job log will show: "IEF450I jobname CICS - ABEND=S000 U1800 REASON=00000000 920".
Problem conclusion
CICS module DFHSJDM has been modified to avoid this 0C4 abend.
Temporary fix
Comments
APAR Information
APAR number
PH37259
Reported component name
CICS TS Z/OS V5
Reported component ID
5655Y0400
Reported release
300
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2021-05-14
Closed date
2021-09-01
Last modified date
2021-10-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI76981
Modules/Macros
DFHSJDM
Fix information
Fixed component name
CICS TS Z/OS V5
Fixed component ID
5655Y0400
Applicable component levels
R300 PSY UI76981
UP21/09/02 P F109
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":"LOB35","label":"Mainframe SW"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.6"}]
Document Information
Modified date:
02 October 2021