IBM Support

PH36827: STA DB COMMAND ISSUED AFTER TS IS ALREADY DROPPED

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • STA DB command issued after TS is already dropped
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of Db2 Object Comparison Tool for      *
    *                 z/OS                                         *
    ****************************************************************
    * PROBLEM DESCRIPTION: Error DSNT302I occurs when running a    *
    *                      work statement list (WSL) that drops    *
    *                      and recreates a table in a classic      *
    *                      partitioned table space.                *
    ****************************************************************
    A change to a column's NULLS attribute results in a drop and
    recreate of the table space, which also drops and recreates
    the table. The WSL contains a -START DB between the DROP and
    CREATE TABLESPACE. Running the WSL for this change results in
    the following error:
    
    DSNT302I !>subsystem name< INVALID NAME >tablespace name<
    

Problem conclusion

  • The issue has been resolved.
    
    Search keywords: MSGSDSNT408 SQLCODE904N RSN00C90080
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH36827

  • Reported component name

    DB2 ADMIN TOOL

  • Reported component ID

    568851500

  • Reported release

    C10

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2021-04-29

  • Closed date

    2021-05-13

  • Last modified date

    2021-06-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI75388

Modules/Macros

  • ADB2CMT
    

Fix information

  • Fixed component name

    DB2 ADMIN TOOL

  • Fixed component ID

    568851500

Applicable component levels

  • RC10 PSY UI75388

       UP21/06/02 P F105

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":"LOB10","label":"Data and AI"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSZJXP","label":"DB2 Tools for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"12.1.0"}]

Document Information

Modified date:
03 June 2021