A fix is available
APAR status
Closed as program error.
Error description
The compiler produces an IGYCB7317-W message for a statement that contains no reference modification, although there is a reference modification on a closely prior statement.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of Enterprise COBOL 6.3 compiling * * programs with reference modifications where * * the bounds of the reference modification are * * either literals or where the optimizer * * determines that the bounds have constant * * known values. * **************************************************************** * PROBLEM DESCRIPTION: Compiler may incorrectly produce * * message "MSGIGYCB7317-W A * * reference-modification length value * * caused reference to be made beyond the * * rightmost character of XXX." for * * data items that are not involved in * * reference modifications. * **************************************************************** * RECOMMENDATION: Apply the provided PTF * **************************************************************** When a data item is used in a reference modification, the compiler generates internal state to indicate that the bounds of the reference modification should be checked, if possible. The optimizer sometimes incorrectly modifies the compiler's internal state to indicate that different data items should be checked.
Problem conclusion
The compiler was fixed to avoid checking reference modification bounds for data item s that are not reference-modified.
Temporary fix
Comments
APAR Information
APAR number
PH36669
Reported component name
ENT COBOL FOR Z
Reported component ID
5655EC600
Reported release
630
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2021-04-26
Closed date
2021-05-19
Last modified date
2021-06-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
IGY8RWTU IGYCASMB IGYCCBE IGYCCCRT IGYCCICS IGYCCSRV IGYCDGEN IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4 IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8 IGYCJA$D IGYCJA$R IGYCLIBR IGYCLSTR IGYCLVL0 IGYCLVL1 IGYCLVL2 IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOB2E IGYCOPI IGYCOPT IGYCOSCN IGYCPGEN IGYCRCTL IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT IGYCSCAN IGYCSIMD IGYCUE$0 IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8 IGYCUE$D IGYCUE$R IGYCXREF IGYDRV IGYEQCWI IGYMSGE IGYMSGK IGYMSGT IGYQCBE IGYQSPLT IGYSIDE2 IGYZQEN6 IGYZQENU IGYZQJP6 IGYZQJPN
Fix information
Fixed component name
ENT COBOL FOR Z
Fixed component ID
5655EC600
Applicable component levels
R630 PSY UI75468
UP21/05/29 P F105
R631 PSY UI75469
UP21/05/29 P F105
R632 PSY UI75470
UP21/05/29 P F105
R63H PSY UI75471
UP21/05/29 P F105
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"630","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
12 December 2023