Error description
sysout2pdf creates malformed MIME-formatted email message
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of CICS PA V5.4 * **************************************************************** * PROBLEM DESCRIPTION: The sysout2pdf z/OS UNIX shell script * * sysout2pdf creates a malformed * * MIME-formatted email message. * **************************************************************** The sysout2pdf z/OS UNIX shell script sysout2pdf creates a malformed MIME-formatted email message in that:- 1) The From email address is enclosed in double quotation marks. This can cause various problems with the formatting of the address. 2) IETF RFC 2046 requires a blank line between the header area and the body area of a IME-formatted message. This blank line is missing, which causes various problems including making attachments unreadable.
Problem conclusion
The sysout2pdf z/OS UNIX shell script has been updated to fix both errors. 1) The From email address is no longer enclosed in double quotation marks. 2) The blank line between the header area and the body area required by IETF RFC 2046 has been added. There is a new sysout2pdf command-line option, savemail: -savemail <file> The savemail option saves the MIME-formatted email message to the z/OS UNIX path specified by <file>, instead of immediately sending an email.
Temporary fix
Comments
APAR Information
APAR number
PH35873
Reported component name
CICS PERF ANALY
Reported component ID
5655Y2300
Reported release
540
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2021-03-31
Closed date
2021-04-14
Last modified date
2021-05-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI74921
Modules/Macros
CPASPX01
Fix information
Fixed component name
CICS PERF ANALY
Fixed component ID
5655Y2300
Applicable component levels
R54S PSY UI74921
UP21/04/21 P F104
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":"LOB35","label":"Mainframe SW"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSPPU4","label":"CICS Performance Analyzer for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.4"}]
Document Information
Modified date:
04 May 2021