A fix is available
APAR status
Closed as program error.
Error description
When trying to maximize throughput of their simple RPT 10.0.2 HTTP test, a customer found that a request which contained a substitution from the Sequential Number built-in datasource was taking substantially longer to execute than expected. The datasource was configured to be shared across all users ("Execute for individual user" was not checked) so that each user would get a unique value. Further testing showed that accessing this datasource could take over a 1000 times longer than a non-shared Sequential Number datasource (where "Execute for individual user" was checked). It is understandable that there would be some increased access time with the shared datasource due to the need to coordinate access among the users but this degree of increase seems unreasonable, especially since the Sequential Number access time is 100s of times larger than the time for a shared dataset.
Local fix
As a workaround, the customer created a dataset with sequential numbers and used this, with Open mode set to "Shared (per test execution) and Access mode set to Sequential, instead of the Sequential Number datasource.
Problem summary
**************************************************************** * USERS AFFECTED: * * RPT Users * **************************************************************** * PROBLEM DESCRIPTION: * * See error description * **************************************************************** * RECOMMENDATION: * ****************************************************************
Problem conclusion
Fixed
Temporary fix
Comments
APAR Information
APAR number
PH35726
Reported component name
PERF TESTER WIN
Reported component ID
5724J9601
Reported release
950
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2021-03-25
Closed date
2021-07-20
Last modified date
2021-07-20
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
PERF TESTER WIN
Fixed component ID
5724J9601
Applicable component levels
RA02 PSY
UP