A fix is available
APAR status
Closed as program error.
Error description
An insufficient storage abend may occur at execution time in a program that uses BIT-OF intrinsic function. Problem occurs when specifying LE run-time options ALL31(OFF) and STACK(,,BELOW,,).
Local fix
Use ALL31(ON) and STACK(,,ANY,,).
Problem summary
**************************************************************** * USERS AFFECTED: Users of Enterprise COBOL 6.3 compiling and * * running COBOL programs that use the BIT-OF * * and/or HEX-OF intrinsic functions as * * arguments to another intrinsic function * * such as REVERSE, and where the argument to * * BIT-OF/HEX-OF is numeric. * **************************************************************** * PROBLEM DESCRIPTION: Insufficient storage abend, U4088-3EC. * **************************************************************** * RECOMMENDATION: Apply the provided PTF. * **************************************************************** For functions BIT-OF/HEX-OF the compiler was not properly calculating the maximum result length of the function when it was used in a nested function invocation and when the argument was numeric.
Problem conclusion
The compiler was updated to properly calculate the maximum length of the return value of the BIT-OF/HEX-OF functions when used in a nested function invocation and the function argument is numeric.
Temporary fix
Comments
APAR Information
APAR number
PH35433
Reported component name
ENT COBOL FOR Z
Reported component ID
5655EC600
Reported release
630
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2021-03-17
Closed date
2021-03-23
Last modified date
2021-04-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
IGY8RWTU IGYCASMB IGYCCBE IGYCCCRT IGYCCICS IGYCCSRV IGYCDGEN IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4 IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8 IGYCJA$D IGYCJA$R IGYCLIBR IGYCLSTR IGYCLVL0 IGYCLVL1 IGYCLVL2 IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOB2E IGYCOPI IGYCOPT IGYCOSCN IGYCPGEN IGYCRCTL IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT IGYCSCAN IGYCSIMD IGYCUE$0 IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8 IGYCUE$D IGYCUE$R IGYCXREF IGYDRV IGYEQCWI IGYMSGE IGYMSGK IGYMSGT IGYQCBE IGYQSPLT IGYZQEN6 IGYZQENU IGYZQJP6 IGYZQJPN
Fix information
Fixed component name
ENT COBOL FOR Z
Fixed component ID
5655EC600
Applicable component levels
R630 PSY UI74566
UP21/03/30 P F103
R631 PSY UI74567
UP21/03/30 P F103
R632 PSY UI74568
UP21/03/30 P F103
R63H PSY UI74569
UP21/03/30 P F103
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"630","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date: